Sep-14 – Rev01 Service Manual Top MountNo Frost Refrigerator Whirlpool of India Ltd.Service ManualTop Moun
10
Identification of connectors: CN1 (Connector 1)(6 pin MLX) – Compressor, Heater and Power Cord CN2 (Connector 2)(8 pin min
Assembly &Disassembly Procedure Disassembly Procedure: A) Core Board Box 1. Disconnect the Power cord from the Mains supply. 2. Remove the M
1. Defrost Sensor mounted on the Evaporator tube. 2. Removing the Defrost Sensor Defrost Temperature Sensor – NTC It’s located at the freeze
Cooling control: Dlx models:- Door Open Sensing Alarm Door open sensing alarm activates or gives beep if the door is kept open for mo
15 Safe mode routine During Constant fault condition, the Electronic Control will assume a safety routine, as in normal cycle, trying to keep food co
16 Board Level Diagnostics for : * Thermistor Failure FC/RC * Potentiometer Failure 1 First Turn Off the Product & disconnect the Plug. 2 Remo
17 EXPLODED VIEWS:
18
19
2 INDEX Sno. Detail Page No. 1.0 Model Range 3 2.0 Safety Precuations 4 3.0 Feature /Tec
20
21
1
24 Note: #61 new part: W10496671 RC PCB LENS ASSY-ONYX WITH INTEGRATED POWER SUPPLY #62 new part: A224104000A FC PCB LENS ASSY-ONY
25 Note: #60 new part: W10512528 H2 CORE BOA
26
NOTE –To replace EMY65HLC Compressor in place of EGZ80HLC use reverse port suction compliment .
28 Part No: - A2241780000 INTEGRATED DEFROST HEATER,KENMORE-ONYX PART LIST FOR ONYX-AUSTRALIA
29 SERVICABLE PART-NEO-AUSTRALIA Sr no WOIL PART NUMBER DESCRIPTION COMMODITY Model 410L 410L 410L 445L WRIBT41WB WRIBP41WC WRIBP41MC WRIBP45WC
3 NO FROST REFRIGERATOR: MODEL RANGE 410L Dlx Better White – WRIBT41WB 410L Dlx Best White – WRIBP41WC 410L Dlx Best Suslite – WRIBP41MC 445L
30 60 W10492990 H2 CORE BOARD BOX SUB ASSY-ONYX AUST ELECTRONICS 1 EA 1 EA 1 EA 1 EA 61 A224099000A RC PCB LENS ASSY - ONYX ELECTRONICS 1 EA 1
5
6 TECHNICAL /FEATURE SPECIFICATION MODEL 410 L Dlx 445 L Dlx Type Frost Free Frost Free Capacities (L) total net 410L 445 L Product Dimension
7 CONTROLS & ELECTRONICS CONFIGURATION Product Configuration No frost Dlx Product Control RC Controlled Software BEE/Pot based Profession
8 Top Mount: Deluxe models: This refrigerator is managed by an Electronic System, mainly consisting of the components: • Electronic Control Boar
9 Wiring Diagram : Top Mount – No Frost Dlx Refrigerant Charging quantity:
Comments to this Manuals