NO
ADJUSTMENT TO DIFFERENT TYPES OF GAS
WARNING
This operation must be performed by a qualied technician.
If the appliance is intended to operate with a dierent gas from the gas type stated on the rating plate and information label on the top of the hob, change the
injectors.
Remove the information label and keep it with the instructions booklet.
Use pressure regulators suitable for the gas pressure indicated in the Instruction:
the gas injector must be changed by After Sales Service or a qualied technician;
injector not supplied with the appliance must be ordered from After Sales Service;
adjust the minimum setting of the taps.
NOTE: when liquid petroleum gas is used (G30/G31), the minimum gas setting screw must be tightened as far as it will go.
IMPORTANT: should you experience diculty in turning the burners knobs, please contact the After Sales Service for the replacement of the burner
tap if found to be faulty.
IMPORTANT: when gas cylinder is adopted, the gas cylinder or gas container must be properly settled (vertical orientation).
REPLACING THE INJECTORS (see the injector table in the Instruction)
Remove grids (A).
Extract burners (B).
Using a socket spanner of the appropriate size unscrew the injector (C), unscrew the injector
to be replaced.
Replace it with the injector suitable for the new type of gas.
Re-assemble the injector in (D).
If you have a multiple crown burner use side spanner to replace the injector (E).
Before installing the hob, remember to ax the gas calibration plate supplied with the injectors in
such a way that it covers the existing information relating to gas calibration.
ADJUSTING MINIMUM GAS SETTING OF TAPS
To ensure that the minimum setting is correctly adjusted, remove the knob and proceed as follows:
tighten screw to reduce the ame height (-);
loosen screw to increase the ame height (+).
The adjustment must be performed with the tap in minimum gas setting position (small ame) :
the primary air of the burners does not need to be adjusted;
at this stage, light up the burners and turn the knobs from max position to minimum position
to check ame stability.
Upon completion of adjustment, reseal using sealing wax or an equivalent material.
REFERENCE TO LOCAL REGULATIONS
GB
Provision for ventilation
The room in which the appliance is installed must have an air supply to current B.S. 5440 - Part 2. All rooms require a permanent vent in addition to the
openable window. If there are other fuel burning appliances in the same room B.S. 5440 - Part 2 should be consulted to determine the air vent requirements.
If the appliance is installed in a cellar or basement, it is advisable to provide an air vent of 65 cm, irrespective of the room volume.
Gas Safety Regulations
The law requires that all gas appliances are installed by competent persons in accordance with the current gas safety regulations. Failure to install appliances
correctly may lead to prosecution. It is in your own interest, and that of safety, to ensure that the law is complied with. The hob should be installed in accordance
with the Gas Safety (Installation and Use) Regulations, the Building Regulations issued by the Department of the Environment and the Building Standard
(Scotland) (Consolidation) Regulations, issued by the Scottish Development Department. In the G.B., CORGI registered installers work to safe standards
of practice.
Page view 2
1 2 3 4 5 6 7

Comments to this Manuals

No comments