Whirlpool UXT3030ADW User Manual

Browse online or download User Manual for Kitchen Whirlpool UXT3030ADW. Whirlpool UXT3030ADW User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 2
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
PRODUCT MODEL NUMBERS
UXT3030AD
Electrical: A 120 volt, 60 Hz., AC only, 15-amp, fused electrical
circuit is required.
30" (76.2 cm) and 36" (91.4 cm) Range Hood
Calculating Vent System Length
To calculate the length of the system you need, add the equivalent feet
(meters) for each vent piece used in the system.
Vent System
Vent Piece
90° elbow 2.5 ft
(0.8 m)
3¹⁄₄" x 10" (8.3 cm x 12.0 ft
25.4 cm) flat elbow (3.7 m)
7" (17.8 cm) wall cap 0.0 ft
(0.0 m)
3¹⁄₄" x 10" (8.3 cm x 4.5 ft
25.4 cm) to 7" (17.8 cm) (1.4 m)
3¹⁄₄" x 10" (8.3 cm x 5.0 ft
25.4 cm) to 7" (17.8 cm) (1.5 m)
90° elbow
Example vent system
Wall cap
90˚ elbow
2 ft (0.6 m)
6 ft (1.8 m)
Maximum Recommended Length
3¹⁄₄" x 10" (8.3 x 25.4 cm)
Rectangular Vent = 35 ft (10.7 m)
1 - 90° elbow = 5.0 ft (1.5 m)
1 - wall cap = 0.0 ft (0.0 m)
8 ft (2.4 m) straight = 8.0 ft (2.4 m)
System length = 13.0 ft (3.9 m)
VENTING METHODS
NOTE: Flexible vent is not recommended. Flexible vent creates both
back pressure and air turbulence that greatly reduce performance.
Flexible vent is not recommended. Flexible vent creates both back
pressure and air turbulence that greatly reduce performance.
The vent system is optional for this model.
Vent system can terminate either through the roof or wall. Use 3¹⁄₄" x
10" (8.3 x 25.4 cm) rectangular with a maximum vent length of 35 ft
(10.7 m).
Top Venting Wall Venting
A
.3¹⁄₄" x 10" (8.3 x 25.4 cm)
rectangular vent through the
roof (purchased separately).
B. Roof cap with damper
(purchased separately)
A. 3¹⁄₄" x 10" (8.3 x 25.4 cm)
rectangular vent through the
wall or out the top (purchased
separately).
B. Wall cap with damper
(purchased separately)
A
B
A
B
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
PRODUCT DIMENSIONS
1"
(2.5 cm)
4¹⁵⁄₁₆"
(12.5 cm)
6⁹⁄₁₆" (16.7 cm)
29¹⁵⁄₁₆" (76.0 cm)
18⁵⁄₈"
(47.3 cm)
1¹⁄₂"
(3.8 cm)
9"
(22.9 cm)
2"
(5.1 cm)
1"
(2.5 cm)
Ref. W10646401B
3/12/14
Page 1 of 2
Page view 0
1 2

Summary of Contents

Page 1 - Example vent system

PRODUCT MODEL NUMBERSUXT3030ADElectrical: A 120 volt, 60 Hz., AC only, 15-amp, fused electricalcircuit is required.30" (76.2 cm) and 36" (91

Page 2 - Installation Clearances

Installation ClearancesA. 18" (45.7 cm) minimum distance from electric cooking surface.24" (61.0 cm) minimum distance from gas cooking surfa