Whirlpool AGB 509/WP Instruction for Use Page 10

  • Download
  • Add to my manuals
  • Print
  • Page
    / 14
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 9
Postioning
Remove all the packaging and check that the appliance is
in perfect conditions. In case of visible damage, do not
connect the appliance and notify the sales point immedia-
tely.
Remove the PVC protection from the panels.
Dispose of packaging according to regulations. Generally
material is divided according to composition and should
be delivered to the waste disposal service.
Maintain a distance of 5 cm between the back (chimney)
of the appliance and the wall. There are no particular pre-
scriptions regarding side distances from other appliances
or walls, however it is advisable to leave enough space in
case of maintenance and/or repairs. It is advisable to fit a
suitable heat insulation if the appliance is in direct contact
with inflammable walls.
The appliance must stand level. Small differences in level
can be eliminated by screwing or unscrewing the adjusta-
ble feet: A significantly uneven or sloping stance can af-
fect the operation of the appliance adversely.
Installation
Warning! : Only qualified technicians must perform
the installation, maintenance and test of the appliance.
Warning! : Before connecting any parts of the
appliance to supplies, make sure that the latter is equi-
valent the requirements stated in the technical data
plate, if the appliance has been designed for these
supplies.
Connection to waterworks
Water inlet pressure must be between 50 and 300 kPa,
otherwise install a pressure regulator on the line before the
appliance.
Install a cut-off valve for each supply on the line before the
appliance.
Water connections to 10 mm are fitted in the lower part on
the left-hand side of the appliance.
Make connections according to regulations currently in
force.
Gas connection procedures
The choice of the gas piping depends on the diameter re-
quired for the type of gas, appliance and installation and
should be performed in conformity with current regula-
tions.
The gas feed plant can either be fixed or be disconnec-
ted; if flexible pipes are employed they must be made
from stainless material and not be affected by corrosion.
If sealing materials are used for connections, they must be
certified and approved for the purpose.
The gas fitting is located on the lower right side of the ap-
pliance
Once the appliance has been connected, carry out a
leakage test on all the fittings connecting the appliance to
the plant. It is advisable to use a leakage spray, otherwise
treat the parts with a foam that does not produce corro-
sion; no bubbles should develop. Carry out the leakage
test also on the rapid cut-off valve.
Warning! : Flames are strictly prohibited for
leakage tests!
Checking the operation of the gas sy-
stem
Check that the appliance has been prepared (category
and type of gas) equivalent to the family of gas available
on site. If not, it is necessary to convert the appliance to
whatever is available. See the paragraph “Conversion to
other types of gas”.
The appliance must be used with the correct injectors for its
thermal power rating (See table page 8 in the “Technical
data”).
The operation of the appliance with its heating capacity
depends on the inlet pressure and the calorific power of
the gas.
The pressure range (inlet pressure) within which the ap-
pliance is allowed to operated is stated in table page 7
“Inlet pressure” of the paragraph “Technical Data”. The
appliance shall not be operated out of the given pressure
range. If pressure should differ from the figures stated in
table page 7, advise the gas board or the company which
has installed the system.
The lower calorific value of the gas can be checked with
the supply company or agency, and should comply with
the information given in table page 8 “Gas data” in the
“Technical data” heading.
Control of the gas inlet pressure
The feed pressure is measured using a liquid pressure
gauge ( e.g. a U-shaped pressure gauge, minimum defi-
nition 0.1 mbar). The supply pressure can be measured
directly at the inlet pressure intake on the gas feed pipe.
The inlet pressure intake can be reached by opening the
lower front panel once the two side screws have been re-
moved. (See figure “Measuring the inlet pressure ”).
Before connecting the manometer, the screw of the pres-
sure port must be loosened.
Connect the U-shaped pressure gauge while the applian-
ce is operating to measure pressure.
The pressure reading on the gauge should be in the ad-
mitted pressure range stated in table page 8 “Inlet pres-
sures” of paragraph “Technical data”.
If pressure figures should not be correct, apply to the gas
board or the company which has installed the system.
Having read the pressure, re-tighten the screw carefully.
Warning! The sealed adjuster screws on the
gas solenoid valve must not be tampered with,
otherwise any guarantee rights shall be forfeited im-
mediately.
POSITIONING, INSTALLATION
AND MAINTENANCE
038
-
03 - Gas kettles 50 lt
10
Page view 9
1 2 ... 5 6 7 8 9 10 11 12 13 14

Comments to this Manuals

No comments