Whirlpool AGB 511/WP Instruction for Use Page 5

  • Download
  • Add to my manuals
  • Print
  • Page
    / 11
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 4
037
-
03 - Electric kettles 50 lt
5
GENERAL REMINDERS
-
Read the warnings contained in this manual carefully as
t
hey provide important information concerning safety du-
r
ing the installation, use and maintenance of the appliance.
-
Keep these instructions carefully!
-
Only personnel trained for its specific use should use the
e
quipment.
-
Keep the appliance under control during use.
-
The appliance should be used only for the purpose for
w
hich it has been specifically designed; other uses are
mproper and hence dangerous.
-
During operation surfaces can become hot and require
s
pecial operation.
-
Unplug the appliance in case of failures or improper ope-
ration.
- Apply exclusively to a service centre for repairs or main-
tenance.
- All important information about the appliance required for
technical service is contained in the technical data plate
(see figure 1).
- In the event of technical assistance being required, the
trouble must be described in as much detail as possible,
so that a service technician will be able to understand the
nature of the problem.
- Gloves should be worn to protect the hands during in-
stallation and maintenance operations.
Warning!: Follow the fire prevention regulations
very carefully.
2 - CHARACTERISTICS OF THE APPLIANCES
3 - TECHNICAL DATA
Model
Width (A)
Depth (B)
Height (C)
Vat diameter
Vat height
Total volume
Usable volume
Voltage/Input
Power
Power cable
Hot water connection
Cold water connection
Water pressure
Pressure
mm
mm
mm
mm
mm
lt
lt
kW
mm
mm
kPa
bar
AGB 511/WP
800
700
900
400
450
58
50
400 V 3N / 230 V 3
9
5 x 1.5 mm
2
/ 4 x 2.5 mm
2
10
10
50 - 300
0.5
The data plate is located on the rigth hand side of the
control panel and contains all the data needed for connecting
it up to the mains electricity supply.
TIPO/TYPE
CAT/KAT GAS/GAZ G30 G31 G20 G25
II2H3B/P P mbar 30 30 20 -
II2H3+ P mbar 30 37 20
-
-
II2H3+ P mbar 28 37 20 -
25II2L3B/P P mbar 30 30
II2ELL3B/P P mbar 50 50 20 20
II2E+3+ P mbar 28 37 20 25
II2H3B/P P mbar 50 50 20 -
I2E P mbar - - 20 -
--II2H3B/P P mbar 30 30
II2H3+ P mbar 28 37 20 -
--
--
I3B/P P mbar 30 30
I3+ P mbar 28 37
SE FI DK CZ SK SI
IT CH PT
ES IE GB GR
NL
DE
FR BE
AT CH
LU
EE LV LT
EE LV LT
NO MT CY IS HU
CY
MOD.
MOD.
ART.
N.
N.
Qn kW
m
3
/h
MADE IN ITALY
Predisposto a gas: - Gas preset: - Prevu pour gaz:
Eingestelt für Gas: - Preparado para gas: -
Geschuckt voor:
V AC kW Hz
THE APPLIANCE MUST BE CONNECTED IN COMPLIANCE WITH THE LAWS IN FORCE
AND INSTALLED IN A WELL-VENTILATED ROOM. READ THE INSTRUCTION MANUALS
BEFORE INSTALLING AND USING THE APPLIANCE.
THE APPLIANCE MUST BE INSTALLED BY QUALIFIED PERSONNEL.
Page view 4
1 2 3 4 5 6 7 8 9 10 11

Comments to this Manuals