Indoor temperatureIndoor temperatureButton is ineffective in Jet mode.Target temperatureTarget temperature21 or below26 or below 22 22 2
10Timer modeHow to set TIMER ON How to cancle TIMER ON TIMER ON button can be used to set the timer programming as wished in order to switch on
1111Operation instructions11SLEEP mode Jet modeSLEEP mode can be set in COOLING or HEATING operation mode.This function gives you a more comfortable
Turn off the appliancefirst before disconnectingfrom power supply.It is necessary to clean the air filterafter using it for about 100 hours.Clean it
Noise pollutionOperating conditionThe protective device maybe trip and stopthe appliance in the cases listed below.COOLINGDRYoOutdoor air temperature
Trouble AnalysisDoes not runNo cooling or heating airIneffective controlDoes not operate immediatelyPeculiar odorA sound of flowing waterCracking soun
Distance from ceilingDistance from wallshould be over 50mmDistance from the wallDistance from floorAir intake distance from the wall should be over 2
Outdoor unitOutdoor unitIndoor unitIndoor unitPipe length is15 meters Max.Pipe length is15 meters Max. be less than 5m be less than 5m Height should
Piping direction1234trough Note: When installing the pipe at the directions 1,2 or 4, saw the corresponding unloading piece off the indoor unit base.
Installation instructionsPiping Joints Thermal Insulation:Wrap the piping joints with thermal insulation materials and then wrap with a vinyl tape.Pip
1Preparation before useThe remote controller is NOT presetting as Cooling Only Air Conditioner or Heat Pump by manufacturer.User can preset the remote
4. Connecting of the CableOutdoor UnitIndoor Unit1). Remove the access door from the unit by loosening Connect the power connecting cord to the indoo
Installation instructionsIndoor unitWiring DiagramMake sure that the color of wires of the outdoor unit and the terminal No. are the same as thoseof t
Fix with bolts and nuts tightly on a flat and strong floor. If installed on the wall or roof, make sure to fix the supporter well to prevent it from s
(1). Unscrew and remove caps from 2 and 3-way valves. (4). Start vacuum pump for 10-15 minutes until reaching a vacuum of 10 mm Hg absolutes. (6). Ope
FANMODETIMER ONCLOCKTIMER OFFSLEEPSWINGONON OFF OFFJETSMARTLOCKSafety precautionsSymbols in this Use and Care Manual are interpreted as shown below
The figures in this manual are based on the external view of a standard model.Consequently, the shape may differ from that of the air conditioner you
The shape and position of the switches and indicators may vary from different models, but their function are similar.Identification of parts4It lights
FANMODETIMER ONCLOCKTIMER OFFSLEEPSWINGONON OFF OFFthsenseLOCKThe remote controller transmits signals to the system.Remote controller51243131256117
How to Insert the BatteriesHow to UseRemove the battery cover according to the arrow direction. Insert new batteries making sure that the (+) and (-)
FANMODETIMER ONCLOCKTIMER OFFSLEEPSWINGONON OFF OFFthsenseLOCKEach time MODE button is pressed, the operation modeis changed in sequence:Each time t
5Airflow direction controlVertical airflow is automatically adjusted to a certain angle in accordance with the operation mode after turning on the uni
Comments to this Manuals