Whirlpool System I User Manual Page 12

  • Download
  • Add to my manuals
  • Print
  • Page
    / 14
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 11
This product has been tested and listed by NSF International under
Standard 42 for Taste, Odor and Chlorine reduction (Class I) and
Particulate reduction (Class II).
Performance Data Sheet
Whirlpool Water Filtration System I
Model No. WSC100YW
SPECIFICATIONS: Taste/Odor/Chlorine reduction (Class I) CAPACITY: 1,000 Gallons
SERVICE FLOW RATE: 0.6 GPM (2.2 Umin) @ 60 psi
General
Performance
Average
Influent
Maximum
Effluent
Minimum%
Reduction
NSF Test
Requirement
Chlorine'
2.0 mg/L <0.1 mg/L 92%
minimum 75%
reduction (Class 1)
Particulate 560,000 part/mL^
18,000 part/mL 98%
minimum 85%
reduction (Class II)
Performance may very based on local water conditions.
^Free Available Chlorine.
n'est requirement is at least 10,000 particles/mL of AC Fine Test Dust.
This product has been tested and listed by NSF International under Standard 42
®) for Taste, Odor and Chlorine reduction (Class I) and Particulate reduction (Class
II) and under Standard 53 for Cyst, Turbidity and Lead reduction.
Whirlpool Water Filtration System II
Model No. WSC200YW
SPECIFICATIONS: Lead and Taste/Odor/Chlorine reduction (Class I) CAPACITY: 500 Gallons
SERVICE FLOW RATE: 0.6 GPM (2.2 Umin) @ 60 psI
General
Performance
Average
Influent
Maximum
Effiuent
Minimum%
Reduction
NSF Test
Requirement
Chlorine’ 2.0 mg/L <0.1 mg/L 92%
minimum75%
reduction (Class 1)
Particulate
560,000 part/mL^ 18,000 part/mL
98%
minimum 85%
reduction (Class II)
Cyst 215,000 4-6 n/mL3
390 4-6 p/mL
99.9%
minimum 99.9%
reduction
Turbidity
14NTU
0.42 NTU
97%
minimum effluent
1.0 NTU
Contaminant
Reduction
Performance^
U.S. EPA
MCL
Average
influent
Maximum
Effluent
Minimum%
Reduction
NSF Test
Requirement
Lead @ pH 6.5 0.015 mg/L 0.16 mg/L^
0.005 mg/L 97%
maximum effluent
0.015 mg/L
Lead @ pH 8.5 0.015 mg/L 0.17 mg/mL®0.002 mg/L
99%
maximum effluent
0.015 mg/L
^Free Available Chlorine.
H'est requirement is at least 10,000 partides/mL of AC Fine Test Dust.
^est requirement is 4-6 micrometer size partides per mL of influent.
^These contaminants are not necessarily in your water supply. Performance may vary based on local water conditions.
®Test requirement 0.15 mg/L± 15%.