SERVICE
Whirlpool Europe ADG 6966 IXM 26.03.2002 / Page 3
Customer Service 8542 966 10750 Doc. No: 4812 718 17747
Technical data
Water pressure
Inlet pressure 0.3 - 10 bar
Spray pump pressure 0.3 bar
Rotations
Spray pump motor 2800 RPM
Drain pump motor 3000 RPM
Spray arm lower 30 - 40 RPM
Spray arm upper 30 - 40 RPM
Fan for drying 2500 RPM
Spray arms, turning rhythm at alternating spray
system
Turning starts every time with the upper spray arm
Pre wash Lower arm ~3min, Upper arm ~1min
Main wash Lower arm ~3min, Upper arm ~5min
Intermediate rinse
Lower arm ~2min, Upper arm ~2min
Final rinse Lower arm ~2min, Upper arm ~2min
Service Test program
Lower arm ~30sec, Upper arm ~30sec
Remark: When switching of the main switch or
interrupt the mains during the Test Program runs,
then the alternating of the spray arms change in
the test program to the rhythm of main wash 5/3
min.
Important: To leaf the Test program is possible by
made a break by customer (pushing the start
button for 1.5 sec.)
After finishing the test program (End LED shines
and/or Start LED goes of) must the appliance be
switched off.
If this will not be done, then the next normal wash
will be made with the frequency of the Service
Test Program ~30/30sec.
Flow rates/ Inlet volume
Flow meter (at 0.3 bar
= quantity 1.1 l/min) 208 lmp/l
Spray pump 45 - 65 l/min
Drain pump 16 l/min
Pump height max. 1.1 m
Inlet valve 4 l/min
Spray arm lower ~ 33 l/min
Sprayarm upper ~ 27 l/min
Shower top ~ 8 l/min
Fan for drying:
Total 900 l/min
Primary air flow 210 l/min
Secondary air flow 780 l/min
Electrical base data
Voltage 220/ 230 V
Frequency 50 Hz
Total power 2.0 - 2.2 kW
Fuse 10 A
Motor
Spray pump motor alternating spray system
Voltage 220/ 240 V
Power consumption 125 W
HI 79
HA 60
Capacitor 4 µ F
Drain pump motor
Voltage 220/ 240 V
Power consumption 30 W
Resistance 146
Fan for drying
Voltage 220 - 240 V
Resistance 141
Heating
1 Element system
Voltage 220/ 230 V
Power consumption 1.87/ 2.04 kW
Resistance 24.5
Heating speed ~ 2.0 ˚C/min
Temperature on surface ~ 115 ˚C
Safety thermostat
self reset
(Temperature of water) ~ 85 ˚C
Fuse 206 ˚C
Potentiometer
Points of meassurement: 1(black) to 2 (middle)
Position 0 0.0 k
Position 1 0.5 k
Position 2 1.0 k
Position 3 1.4 k
Position 4 1.8 k
Position 5 2.3 k
Position 6 2.6 k