Door Open Sensing Alarm
Door open sensing alarm activates or gives beep if the door is kept open for more than 2 min.
During the Door opening beep alarm if the door is closed then the alarm gets deactivated
.
Alarm Codes, Priority, Retention and Trigger
Alarm code for Deluxe models: -
In event of any Fault accurring for RC/FC or Pot sensors then immediately after 2 min’s of the
fault occurrence a Buzzer Beep for 1 Sec will be activated indicating the Sensor fault condition in
Dlx models only.
To understand where there is any Sensor or Pot failure indication in the Dlx model, Service Person
should Switch On the Product & wait for the any buzzer Beep if any after 5 sec of Product switch
ON. This will indicate the Error status in the Dlx models.
Check Point:
- Poor contact between terminals/ connectors – CN2 (Temperature Sensors) at Electronic Control
(main board)
- The Sensor/Pot itself that might be open or in short circuit and has to be replaced (see Sensor/Pot
replacement).
Safe mode routine
During Constant fault condition, the Electronic Control will assume a safety routine, as in normal
cycle, trying to keep food conservation, however will work as follows:
• Compressor and Fan Motors will be on for 25 minutes and then will turn off for 20 minutes.
• Interval set between defrosts will be fixed in every 5 hours of the Compressor activity
• Every defrost time is fixed for 20 minutes. No dependency on defrost sensor for Cut Off temp of
15°C
Normal
Compressor
/Product
running
Mode
Sensor
Failed??
(Open/Shor
t Mode)
{RC, FC or
Ambient
Sensor)
Start Safe mode
routine
after 2 min of
error
Event in sensor
Yes
Normal
Compressor
/Product
running
Mode
No
Whether
sensor/POT
is
repaired/correc
ted??
No
Yes
Page view 14