NUTID HGA4K COOKING HOB OPERATING INSTRUCTIONS Destinations
GB
To ensure best use of the hob, please read these instructions carefully and keep them for future reference.
5019 619 01326/A
HBN 410
FR BE
Operation of gas burners with safety and electric ignition
To light one of the burners:
• Press and turn the corresponding knob anticlockwise to
the large flame symbol .
• At the same time, keep the knob pressed against the
control panel until the burner ignites .
The igniter spark will light the burner.
• Once the burner is lit, keep the knob pressed for about
10 seconds.
• Release the knob.
If the burner fails to light, repeat the above steps.
Note:
The burner safety device shuts off the gas if the flame goes
out accidentally (sudden draughts, interruption in gas
delivery, boiling over of liquids, etc.).
The device must not be pressed for more than 15 sec. If the
burner does not stay alight after this time has elapsed, wait at
least one minute before trying to light it again.
Important:
Improper use of the grates could scratch the hob: do not
place the grates upside down and/or slide them on the hob.
It is inadvisable to use:
• cast iron grills or earthenware pots and pans
• dissipators such as metal mesh etc.
• two burners simultaneously for one container (e.g. fish
kettle).
HOB DIMENSIONS (mm)
NOTES: If a hood is installed above the hob, refer to the hood assembly instructions for the correct
distance to be respected.
1. Removable grates
2. Rapid burner
3. Auxiliary burner
4. Semi-rapid burners
5. Rear right semi-rapid burner control knob
6. Rear left semi-rapid burner control knob
7. Front left rapid burner control knob
8. Front right auxiliary burner control knob
Symbols
Solid disc Tap closed
Large flame Max. opening/max. delivery
Small flame
Min. opening or reduced
delivery
INJECTOR TABLE CATEGORY II2E+3+
POWER SUPPLY: 230V ~ 50Hz
BEFORE USING THE HOB
These instructions are only valid for the countries whose
symbol is given on the dataplate (under the hob).
• Keep the packing elements (plastic bags, polyurethane
foam, etc.) out of the reach of children, as they are a
potential source of danger.
• Use a detergent recommended for cleaning the stainless
steel hob and remove and deposits of fat or food. Before
using the hob, make sure to remove any stickers.
• Make sure the hob was not damaged during transport.
• Make sure installation and the gas/electrical
connections are carried out by a qualified technician
according to the Manufacturer's instructions and in
compliance with the current local regulations.
SAFEGUARDING THE ENVIRONMENT
Packing
The packing materials are 100% recyclable and marked with
the recycling symbol ( ).
Products
This appliance is marked in compliance with European
Directive 2002/96/EC on Waste Electrical and Electronic
Equipment (WEEE). By ensuring that this appliance is
correctly scrapped, the user can help prevent potentially
harmful consequences for the environment and the health of
people.
The symbol on the product or accompanying
documentation indicates that this product should not be
treated as domestic waste but must be taken to a suitable
centre for collection and recycling of electrical and electronic
equipment. Disposal must be carried out in compliance with
local regulations on waste disposal.
For further information on the treatment, recovery and
recycling of this product, contact your competent local office,
the household waste collection service or the shop where you
purchased the appliance.
Type of gas used Type of burner Injector
marking
Nominal heating
capacity
kW
Nominal
consumption
Reduced heating
capacity kW
Gas pressure
(mbar)
BE FR
min. nom. max.
NATURAL GAS
(Methane)G20
rapid
semi-rapid
auxiliary
128
104
78
3.00
1.90
1.00
286 l/h
181 l/h
95 l/h
0.80
0.45
0.35
0.60
0.35
0.30
17 20 25
NATURAL GAS
(Methane)G25
rapid
semi-rapid
auxiliary
128
106
78
3.00
1.90
1.00
332 l/h
210 l/h
111 l/h
0.60
0.35
0.30
20 25 30
LIQUEFIED
PETROLEUM GAS
(Butane) G30
rapid
semi-rapid
auxiliary
87
70
50
3.00
1.90
1.00
218 g/h
138 g/h
73 g/h
0.60
0.35
0.30
20 28-30 35
LIQUEFIED
PETROLEUM GAS
(Propane) G31
rapid
semi-rapid
auxiliary
87
70
50
3.00
1.90
1.00
214 g/h
136 g/h
71 g/h
0.60
0.35
0.30
25 37 45
Type of gas used Model configuration Nominal heating capacity
kW
Total nominal
consumption
Air necessary (m
3
) for the
combustion of 1 m
3
of gas
G20 20 mbar 4 gas 7.80 743 l/h 9.52
G25 25 mbar 4 gas 7.80 863 l/h 8.187
G30 28-30 mbar 4 gas 7.80 569 g/h 30.94
G31 37 mbar 4 gas 7.80 557 g/h 23.80