TGWI 5377 PRODUCT DESCRIPTION SHEET
GB
5019 419 02026
To get full satisfaction from the hob, please read these instructions carefully and keep them for future consultation.
NL
USE OF THE GAS BURNERS
• To ignite one of the burners, turn the relative knob anti-clockwise to the maximum flame setting.
• Press the knob against the control panel to ignite the burner.
• After the burner has ignited, keep the knob pressed for about 5 seconds to allow the thermocouple to warm up.
This burner safety device shuts off the gas supply to the burner if the flame goes out accidentally (because of sudden
draught, an interruption in the gas delivery, boiling over of liquids, etc.).
• The device must not be pressed for more than 15 sec. If, after that time has elapsed, the burner does not
remain lit, wait at least one minute before trying to light it again.
- The burner might go out when the knob is released. This means that the thermocouple has not warmed up enough.
In this case, repeat the operations described above.
PRACTICAL ADVICE FOR USING THE GAS
BURNERS
For optimum burner performance, observe the following
rules:
- Use pots and pans that fit the burners (see table on the
right).
- Only use flat-bottomed pots and pans.
- Use the correct amount of water for cooking foods and
keep the pot covered.
- In the case of pans with convex bottoms (WOK), use
the adapter provided, which must be positioned on the
4-ring burner only
PRACTICAL ADVICE FOR USING THE
INDUCTION COOKING ZONE
- Use only pots with the symbol “INDUCTION SYSTEM”
- For existing pots and pans, use a magnet to check
suitability: pots are unsuitable if they cannot be
magnetically detected
- Use pots and pans that fit the burners (see table below)
4
57
3 2
6
1
8
9
1. Removable panstand grids
2. 4 ring burner
3. Semi-rapid burner
4. Auxiliary burner
5. 4 ring burner control knob
6. Semi-rapid burner control knob
7. Auxiliary burner control knob
8. Induction zone control panel
9. Induction cooking zone
SYMBOLS
tap closed
Maximum flame
Minimum flame
Induction on/off
Induction key lock
Timer
Burner Pot Ø
Auxiliary
from 8 to 14 cm
Semi-rapid
from 16 to 22 cm
4 ring
from 24 to 26 cm
Induction zone Pot Ø
Ø 24 cm
from 14 to 24 cm
DIMENSIONS AND DISTANCES TO BE MAINTAINED (mm)
NOTE: If the distance “A” between the wall cabinets is between 600 mm and 730 mm, the height “B” must be
a minimum of 520 mm.
If the distance “A” between the wall cabinets is greater than the width of the hob, the height “B” must
be a minimum of 400 mm.
In the event a hood is fitted above the hob, please refer to the hood assembly instructions for the
correct distance.
INJECTOR TABLE CATEGORY II2L3B/P
ELECTRICAL SUPPLY: 230 V ~ 50 Hz
ELECTRIC HOB OUTPUT: 3000 W
Type of gas used Type of
burner
Injector
marking
Rated thermal
flow rate
kW
Rated
consumption
Reduced heat
capacity kW
Gas pressure (mbar)
min. rat. max.
NATURAL GAS
(Methane) G25
4 ring
semi-rapid
auxiliary
142
100
79
3.50
1.65
1.00
389 l/h
183 l/h
111 l/h
1.70
0.35
0.35
20 25 30
LIQUID
PETROLEUM GAS
(Butane-Propane) G30-G31
4 ring
semi-rapid
auxiliary
90
67
50
3.20
1.65
1.00
233 g/h
120 g/h
73 g/h
1.55
0.35
0.35
25 30 35
Type of gas used Model
configuration
Rated thermal flow
rate kW
Total rated consumption Air necessary (m
3
) for the
combustion of 1 m
3
of gas
G25 25 mbar 3 burners 6.15 683 l/h 8.187
G30-31 30 mbar 3 burners 5.85 426 g/h 30.94
Comments to this Manuals