45
Malfunction Cause
Indoor unit makes noise
The sound comes from the fan or compressor relay switching over
(close/open).
Air conditioner may make noise in defrost mode or when stopped
due to inverse flow of refrigerant in the unit
No air blows out of indoor unit
When the temperature of the indoor heat exchanger is low during
heating process, the indoor unit will stop air blowing to prevent
blowing of cold air (for 3 minutes).
In heating mode, if the outdoor temperature or humidity is high and
the outdoor heat exchanger has more frost, the air conditioner will
activate the auto defrost function and the indoor unit will stop air
blowing for 6/8~10 minutes.
During defrost, water or steam may flow from the outdoor unit.
In dehumidify mode, the fan on the indoor unit may stop to prevent
evaporation of condensing water and rise of temperature.
Moisture on outlet grill
If the air conditioner is left running in high humidity, moisture may
condense on the grill and accumulate there.
In case of the following events, please contact the Whirlpool Authorized Service Center nearest you.
Stop the air conditioner and pull
out the power plug.
The air conditioner makes a shrill noise when running.
Air conditioner gives out an unpleasant odor when running.
Water leaks from the indoor unit.
Air break switch or leakage protection switch drips frequently.
Foreign matter or water enter the machine or remote control.
Abnormal overheating of power cord and plug.