W11101341A W11101343A-SPDRYER SAFETY ... 2INSTALLATION REQUIREMENTS ...
103-wire Power Supply Cord ConnectionUse where local codes permit connecting cabinet-ground conductor to neutral wire. A. 3-wire receptacle (NEMA typ
114-wire Direct Wire Connection IMPORTANT: A 4-wire connection is required for mobile homes and where local codes do not permit 3-wire connections. Di
123-wire Direct Wire ConnectionUse where local codes permit connecting cabinet-ground conductor to neutral wire. B5. Remove center screwRemove center
13BCE2. Connect neutral ground wire and neutral wireConnect neutral ground wire (E) and neutral wire (white or center wire) (C) of power supply cord
14Exhaust hoods: Must be at least 12" (305 mm) from ground or any object that may obstruct exhaust (such as owers, rocks, bushes, or snow).E
15The “Vent System Charts” provides venting requirements that will help achieve best drying performance.Special provisions for mobile home installatio
16Turn cold water faucet off and remove washer inlet hose.Remove old rubber washer from inlet hose and replace with new rubber washer. For non-steam
17CONNECT VENT1. Connect vent to exhaust outletUsing a 4" (102 mm) clamp, connect vent to exhaust outlet in dryer. If connecting to existing ven
182. Tighten and adjust leveling legsIf dryer is not level or the same height as the washer, prop up using a wood block. Use wrench to adjust legs up
19REVERSE DOOR SWING (Optional)Lift door until top screws in dryer cabinet are in large part of hinge slot. Pull door forward off screws. Set door (ha
2DRYER SAFETY
TROUBLESHOOTINGSee the Use and Care Guide or visit our website and reference “Frequently Asked Questions” to possibly avoid the cost of a service ca
4 Level Caulking gun and compound (for installing new exhaust vent)If using a power supply cord:Use a UL-listed power supply cord kit marked for use w
5You will need: A location allowing for proper exhaust installation. See “Venting Requirements.” A separate 30 amp circuit. If you are using po
6Minimum Required Spacing3"(76 mm)3"(76 mm)24 in.2(155 cm2)48 in.2(310 cm2)18"(457 mm)1"(25 mm)1"(25 mm)51/2"(140 mm)14&
71. Prepare dryer for leveling legsTo avoid damaging oor, use a large at piece of cardboard from dryer carton; place under entire back edge of dryer
8ELECTRICAL CONNECTIONPower Supply CordElectrical Connection Options1. Choose electrical connection typePower supply cord 4-wire receptacle(NEMA Type
9Put power supply cord through the strain relief. Be sure that the wire insulation on the power supply cord is inside the strain relief. The strain re