Gas Thin Twin Washer/Dryer
PRODUCT MODEL NUMBER OVERALL DIMENSIONS
RECESSED AREA AND CLOSET INSTALLATION
EXHAUST VENTING
LG5243DQ
Gas supply: Dryer is equipped for use with
NATURAL gas. Dryer can be converted to L.P. gas.
When rigid pipe is used it should be 1/2 inch IPS.
When acceptable to the gas supplier and local
codes, 3/8-inch approved tubing may be used for
lengths under 20 feet. For lengths over 20 feet,
larger tubing should be used. Pipe-joint
compounds resistant to the action of L.P. gas must
be used. This washer/dryer is equipped with its
own permanent, flexible gaas connector, design-
certified by CSA International, for connecting the
appliance to the gas supply line. An individual
manual shutoff valve must be installed within 6
feet of the dryer in accordance with the National
Fuel Gas Code ANSI Z223.1.
Electrical: A 120-volt, 60-Hz, AC-only, electrical
supply is required on a seperate 15- or 20-ampere
circuit, fused on both sides of the line. A time-
delay fuse or circuit breaker is recommended.
Exhaust venting: Exhaust your dryer to the
outside. Four-inch diameter vent is required. Rigid
or flexible metal exhaust vent must be used. Do
Not use plastic or metal foil vent. Exhaust outlet
hood must be at least 12 inches from the ground
or any object that may be in the path of the
exhaust.
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
Ref. 3405971
06-01-02
4-3/8"
recess
depth
1-1/2"
14-1/4"
recess width
rear view
cold
water inlet
28-5/8"
24"
drain
outlet
27-1/2"
exhaust
outlet
38"
19"
12"
12"
71-3/4"
27-1/4"
side view
38"
5-1/4"
21-5/16"
15-3/8"
32-1/8"
57"
47"
51-1/2"
27-5/8"
0"
side view
12"
0"
dryer
washer
front view
0"
48 sq. in.*
24 sq. in.*
24 sq. in.*
3"
3"
front view
side view
48 sq. in.*
0"
Unobstructed air openings are minimum for closet door.
Louvered door with equivalent air openings is acceptable.
1"
closet
door
closet
door
The maximum length using a 2" x 6" rectangular vent
with 2 elbows and a 2-1/2" exhaust hood is 8 ft.
43 ft
33 ft
23 ft
18 ft
0
1
2
3
41 ft
31 ft
21 ft
18 ft
29 ft
23 ft
15 ft
9 ft
24 ft
18 ft
10 ft
Not
recommended
36 ft
26 ft
16 ft
Not
recommended
0
1
2
3
flexible
metal
vent.
rigid
metal
vent.
Maximum
length of
4" dia.
vent.
4"
4"
2-1/2"
NUMBER
OF 90°
TURNS
30 ft
24 ft
16 ft
10 ft
Plan installation to use the fewest number of
elbows and turns.
Maximum length of the exhaust system depends
upon the type of vent used, number of elbows and
the type of exhaust hood. The maximum length for
both rigid and flexible vent is shown in the chart.
Additional clearance for wall, door and floor molding may be
required. Additional space may be needed for exhaust elbow.
Page view 0
1

Summary of Contents

Page 1 - Gas Thin Twin Washer/Dryer

MinimuminstallationspacingClosetconfinedareaRecessedareaMinimuminstallationspacing®Gas Thin Twin Washer/DryerPRODUCT MODEL NUMBER OVERALL DIMENSIONSRE

Comments to this Manuals

No comments