Whirlpool WFW3090GW Instruction for Use Page 5

  • Download
  • Add to my manuals
  • Print
  • Page
    / 24
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 4
PAGE 5
FOR SERVICE TECHNICIAN’S USE ONLY
DO NOT REMOVE OR DESTROY
NOTE:
The total duration of the Service Test Cycle is approximately 5 minutes. During the Service Test Cycle, all UI LEDs will be on
except for the “door open/door unlocked” LED. The display will show the test step sequence.
Do not skip test steps. Washer must be connected to water supply when performing Service Test Cycle.
The following indicates the basic meaning of each “F##” fault/error code. See the chart beginning on page 7 for more details.
F01 = Water flow F20 = Main relay or heater relay
F03 = Drain pump F21 = UI communication
F04 = Heater timeout F24 = Overflow
F05 = Temperature sensor F26 = Drain pump
F06 = Motor rotor F27 = Motor
F07 = Motor control (internal failure) F29 = Door lock
F10 = Motor control (over temp.) F34 = Motor spin
F13 = ACU door lock F36 = Analog pressure sensor
F18 = Suds detected F60 = ACU internal failures
SERVICE TEST CYCLE CHART
NOTE: Perform Service Test Cycle without laundry in the washer.
Step Icon Description Checks performed
C00
Door is locked. ACU is performing
the self test.
ACU detects F05, F07, F13, F20,
F21, F24, F26, F27, F29, F60.
C01
Prewash valve fills for 6 seconds.
Main wash valve fills for 6 seconds.
Prewash and main wash valves
both fill for 16 seconds.
Prewash and main wash valves
both fill to wash level.
Motor turns on.
Verifies activation of valves,
dispenser, and pressure sensor.
ACU detects F01, F06, F07, F10.
C02
Heating element turns on for
15 seconds. Motor is off. Display
shows a measured temperature,
e.g., 20C = 20°C (68°F).
Verifies activation of heating
element, correct measurement
of cold water temperature.
NOTE: Heating time is very
short; no noticeable actual temp.
increase.
C03
Drain pump turns on until reaches
wash level + 8 seconds.
Motor reverses.
Verifies activation of drain pump
and reversal of motor.
ACU detects F03, F06, F07, F15,
F26, F27.
C04
Unbalance and load size
is measured. Display shows
amount of measured unbalance
in kg (example: “0:03” = 0.03 kg
[30 grams] of unbalance).
Motor revs to maximum speed.
Drain pump turns on.
Verifies that motor is running
at maximum speed.
Verifies the displayed unbalance.
Verifies activation of drain pump.
ACU detects F06, F07, F28, F34.
C05
Motor turns off (brakes).
Door is unlocked.
Washer turns off.
Verifies unlocking of door and
turning off of washer.
ACU detects F13, F29 (FdL).
Page view 4
1 2 3 4 5 6 7 8 9 10 ... 23 24

Comments to this Manuals