7322259 (Rev K 4/17/13)Product No. 8576162BManufactured and warranted byEcodyne Water Systems1890 Woodlane DriveWoodbury, MN 55125How to install, ope
Step C - Install RO Filter Assembly10INSTALL STORAGE TANK1. Apply thread sealing tape (2 wraps clockwise) tothe threads on the nipple at the top of t
Step E - Install RO Faucet11You will need to select the location of the ReverseOsmosis Faucet. You have three options to choosefrom:• Use the existin
Step E - Install RO Faucet (cont.)12INSTALL REVERSE OSMOSIS FAUCET1. Locate and organize your RO faucet install parts. Refer toFig. 15. 2. Mount fauce
Step F - Connect Tubes13HOW TO CUT AND CONNECT THE TUBESYour Reverse Osmosis system includes push-in fittingsfor quick tubing connection. Review the f
Step F - Connect Tubes (cont.)14ROUTE YELLOW TUBE TO STORAGE TANK1. Locate the yellow tube attached to the Reverse Osmosisfilter assembly. 2. Route th
Step G - Sanitize, Test and Purge System15SANITIZE THE SYSTEMSanitizing is recommended immediately after installa-tion of the Reverse Osmosis system.
Step G - Sanitize, Test and Purge System (cont.)16StorageTankWater Supply ShutoffValve to ReverseOsmosis SystemHOT COLDFIG. 25ReverseOsmosisFaucetK
How Your RO Water System Works17HOW YOUR REVERSE OSMOSIS SYSTEMWORKSIntroduction: Your Reverse Osmosis (RO) DrinkingWater System uses your household w
How Your RO Water System Works18Water Flow Description1. Water enters prefilter. Sand, silt and other sediments are reduced. Chlorine is also reduced.
Maintenance19PREFILTER / POSTFILTER MAINTENANCENOTE: It is recommended to replace the battery,prefilter and postfilter cartridges at least every 6mont
TABLE OF CONTENTSPageSpecifications & Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Maintenance20FLOW CONTROLThe flow control is required for proper operation of theReverse Osmosis system. See Fig. 28. The flow control,located inside
Troubleshooting21Problem: Chlorine taste and/or odor in the RO product water.Cause: The level of chlorine in your water supplyexceeds maximum limits,
Exploded View22Questions? Call Toll Free 1-866-986-3223 Monday- Friday, 8 AM - 7 PM ESTor visit www.whirlpoolwatertreatment.comWhen you call, please b
23To order repair parts call toll free 1-866-986-3223, Monday - Friday, 8 am - 7 pm EST.Manufactured and warranted byEcodyne Water Systems1890 Woodlan
Specifications & Dimensions3Questions? Call Toll Free 1-866-986-3223 Monday- Friday, 8 AM - 7 PM ESTor visit www.whirlpoolwatertreatment.comWhen y
Inspect Shipment4Your Reverse Osmosis Drinking Water System isshipped complete in one carton. Remove all itemsfrom your shipping carton. Check all ite
Plan Your Installation5Read through the entire manual before beginningyour installation. Follow all steps exactly. Readingthis manual will also help y
Overview and Site Preparation6OVERVIEWRead through the entire manual before beginning yourinstallation.There are seven steps to installing your Drinki
7Step A - Install Supply Water FittingCold Water Supply Connection(using included water supply fitting)1/4” green tubingto ReverseOsmosis inletwater s
Step B - Install RO Drain Under Sink8INTRODUCTIONA suitable drain point is needed for the drain waterfrom the Reverse Osmosis Filter. You have two opt
Step B - Install RO Drain in Remote Location9INSTALL A REMOTE DRAIN POINT ANDAIR GAP (Remote Location)Route the drain tubing to an existing drain in t