Whirlpool HXC9.8AT User Manual Page 12

  • Download
  • Add to my manuals
  • Print
  • Page
    / 16
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 11
12
GB
PLEASE PHONE US TO REGISTER YOUR APPLIANCE AND ACTIVATE YOUR PARTS GUARANTEE ON 08448 24 24 24
Antigrease and odour lter signal
Theantigrease(A)and/orodour(B)ltersneedcleaning/
replacing after a certain number of hours of use (the latter
forlteringhoodsonly).
The indicator light I1onindicatesthattheantigreaselter
is saturated, while the indicator light I2 on indicates that the
odourlterissaturated(forhoodsinlteringmodeonly).
Press T5 + T4 for 3 seconds with the hood on to reset the
counter.
Hood type setting
Thehoodcanbesettotheventilation(default)orltering
mode. To change the setting proceed as follows:
• withthehoodOFF, the menu is accessed by pressing the
T4 e T5 buttons for a prolonged time; this is signalled by
a sound emitted by the hood and by the I4 icon lighting
up and the writing C1-0 appearing on the display;
• usethebuttonsT4 and T5 to go through the menu. Use
T4 to go through the various menu items (C1, C2, C3,
C4, etc) and T5 to select them (0, 1 or 0, 1, 2);
tosetthehoodtype,accessthemenu,selecttheitemC6 with
T4 and set the value 0 with T5 to set the hood on ventilation
modeor1forthelteringmode.PressT1 at the end.
Hood off
The hood can be turned off manually by pressing the T1
button (ON/OFF). If the hood stays on in manual mode, it
turnsoffautomaticallyafteracertain“safety”time.Ifthe
timer is set, the hood turns off automatically when the set
time runs out.
Models with Touch control glass + display
(high)
(Only available in certain models)
T1 T2 T3 T4 T5 T6 T7 T8
T1 motor ON/OFF
Whenthebuttonispressedwiththehoodoff,therstspeed
is set. When the button is pressed during operation, the
hoodswitchesOFF.
T2 Speed –
When the button is pressed the hood switches to the
previous speed.
T3 Speed +
When the button is pressed the hood switches to the next speed.
If the hood is off, speed 1 is set when pressing this button.
T4 Booster
When the button is pressed, the hood switches from the
previousstatustotheintensivespeed;theletterb”willash
slowly on the display. The setting has a limited timeframe;
when the time elapses the hood goes back to the speed set
previously; when a speed button is pressed (T2, T3 or T4),
the selected speed is set as you leave the booster mode.
T5 AUTO
Press the T5 button to activate the automatic mode, which
turns the hood on based on the steam level detected. While
in normal operation the sensor regulates the motor speed
within the admitted values (0,1,2,3 or booster). The hood
switchesfromautomatictomanualmodewhentheBooster
or Speed button is pressed.
The sensor needs calibrating before use; for more
information please refer to paragraph “Calibration
procedure”
T6 Timer “–”
With the timer, a time can be set, after which the hood
turns OFF; if the timer is set and the speed is subsequently
changed by pressing T2, T3 or T4, the timer is deactivated.
Press the T6 button to decrease the previously set value
by 5 minutes.
T7 Timer “+”
Whenthebuttonispressedforthersttime,thetimerisset
to 5 minutes; this value is increased by 5 additional minutes
every time the button is pressed after that.
T8 lights ON/OFF
It turns the work lights of the hood on and off.
D1I1 D2 I5
I2 I4
D1: DGT Speed
D2: Assembly of 2 DGT Time
I1:GreaseFilterIndicator
I2:CarbonFilterIndicator
I4: Menu Indicator
I5: Timer Indicator
Antigrease and odour lter signal
The antigrease (A) and odour (B) lters need cleaning/
replacing after a certain number of hours of use (the latter
forlteringhoodsonly).
The indicator light I1onindicatesthatthegreaselteris
saturated, while the indicator light I2 on indicates that the
odour/carbonlterissaturated(forhoodsinlteringmode
only).
Press T5 + T6 for 3 seconds with the hood on to reset the
counter.
Automatic sensor calibration procedure
- Calibration: the calibration procedure must be carried
out in a clean environment to be effective; therefore, the
hob must be off during the calibration.
During the calibration procedure the AUTO button is on
and the AUTOwritingashesonthedisplay.
The sensor calibration may be automatic or manual
(“uponrequest”).Inbothcasesthecalibrationlasts:
• about1minuteforgashobs;
• about13minutesforinductionandelectrichobs.
- Automatic calibration: occurs when the hood is power
suppliedorafterselectingtheplanfromtheconguration
menu.
Page view 11
1 2 ... 7 8 9 10 11 12 13 14 15 16

Comments to this Manuals

No comments