NATURAL GAS TO PROPANE CONVERSION KIT
ALPKT572-2 INSTALLATION INSTRUCTIONS
PROPANE CONVERSION KIT SAFETY
Table of Contents
PROPANE CONVERSION KIT SAFETY........................................1
INSTALLATION REQUIREMENTS................................................2
Tools and Parts ............................................................................2
LP Gas Requirements..................................................................2
INSTALLATION INSTRUCTIONS..................................................3
Remove Low NOx Inserts ............................................................3
Convert Furnace...........................................................................4
Make Gas Connections..............................................................10
Check the Furnace Input Rate ...................................................10
Adjust the Furnace Input Rate ...................................................11
Complete Installation..................................................................12
Models WFAR, WFAT, WFAU, WFCH, WFCU, WFLR, WFLU, WFLT
G1N80AR, G1N80AT, G1N80AU,
G1D80AR, G1D80AT, G1D90AH, G1D91AU,
CG80RA, CG80TA, CG80UA, CG90HA, CG90UA
4
5900D003
You can be killed or seriously injured if you don't
immediately follow instructions.
You
can be killed or seriously injured if you don't
follow instructions.
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you
what can
happen if the instructions are not followed.
Your safety and the safety of others are very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all
safety messages.
This is the safety alert symbol.
This symbol alerts you to potential hazards that can kill or hurt you and others.
All safety messages will follow the safety alert symbol and either the word “DANGER” or
“WARNING.” These words mean:
WARNING
This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer’s instructions and
all applicable codes and requirements of the authority having jurisdiction. If the information in these instructions is not
followed exactly, a fire, explosion, or production of carbon monoxide may result, causing property damage, personal
injury, or loss of life. The qualified service agency is responsible for the proper installation of this kit. The installation is not
proper and complete until the operation of the converted appliance is checked as specified in the manufacturer’s
instructions supplied with the kit.
Page view 0
1 2 3 4 5 6 ... 11 12

Summary of Contents

Page 1 - PROPANE CONVERSION KIT SAFETY

NATURAL GAS TO PROPANE CONVERSION KITALPKT572-2 INSTALLATION INSTRUCTIONSPROPANE CONVERSION KIT SAFETYTable of ContentsPROPANE CONVERSION KIT SAFETY..

Page 2 - INSTALLATION REQUIREMENTS

10Make Gas Connections1. Install the field gas supply as shown.2. Provide a sediment trap on the outside of the furnace.3. Install a manual gas shutof

Page 3 - INSTALLATION INSTRUCTIONS

11Adjust the Furnace Input Rate (if required)IMPORTANT: Follow these instructions for the altitude of your installation. Above 10,000 ft: Furnace is

Page 4 - Convert Furnace

Complete InstallationIMPORTANT: Do not use this furnace if any part has been under water. Immediately call a qualified person to inspect the furnace a

Page 5 - Gas Control Valve

2ADDITIONAL SAFETY INFORMATIONINSTALLATION REQUIREMENTSThese instructions are intended as a general guide only and do not supersede any national or lo

Page 6

3INSTALLATION INSTRUCTIONS\Remove Low NOx Inserts(on some models)This section refers only to models that contain an “L” in the full model number. If y

Page 7

47. Remove the screws fastening the low NOx inserts to the panel. The tabs attached to the low NOx inserts will remain on the inserts.8. Slide the low

Page 8 - Horizontal Furnace Conversion

56. Remove the regulator adjustment cap with “O” ring, pressure regulator adjusting screw, and spring from the gas control valve. See “Gas Control Val

Page 9

6Closed Burner Box Furnace ConversionIMPORTANT: This section refers only to models WFCU, GID80AR, GID80AT, GID91AU, and CG90UA.1. Turn off gas supply

Page 10 - (if required)

79. Convert the Gas Control Valve for LP Gas. Open the plastic bag included in this kit. Locate the new spring (different color) and install. Locat

Page 11

8Horizontal Furnace ConversionIMPORTANT: This section refers only to models WFCH, CG90HA, and GID90AH. LP adapter plates are not required for these mo

Page 12 - Return Air

910. Remove the regulator adjustment cap with “O” ring, pressure regulator adjusting screw, and spring from the gas control valve. See “Gas Control Va