IMPORTANT: Save for local electrical inspector’s use.
INSTALLATION INSTRUCTIONS
30" (76.2 CM) FREESTANDING GAS RANGE
with standard clean oven
W10032050
Table of Contents..................................................2
Page view 0
1 2 3 4 5 6 ... 15 16

Summary of Contents

Page 1 - INSTALLATION INSTRUCTIONS

IMPORTANT: Save for local electrical inspector’s use.INSTALLATION INSTRUCTIONS30" (76.2 CM) FREESTANDING GAS RANGEwith standard clean ovenW100320

Page 2 - RANGE SAFETY

10Check OperationElectronic Ignition SystemCooktop and oven burners use electronic ignitors in place ofstanding pilots. When a cooktop control knob is

Page 3

113. Locate the air shutter near the rear wall of oven and loosenthe shutter screw.4. Adjust the air shutter. 5. Turn the oven back on and check for p

Page 4 - Model/serial

122. Unplug or disconnect power.3. Open broiler door and remove broiler pan. The gas pressureregulator is located in the back right hand corner of the

Page 5 - Product Dimensions

2. Locate LP gas orifice spuds for top burners in the bagcontaining literature included with the range. Three LP gasspuds are stamped “88” and one “96

Page 6 - Electrical Requirements

142. Locate the natural gas orifice spuds for the top burners in thebag containing literature included with the range. Threenatural gas spuds are stam

Page 7 - Gas Supply Pressure Testing

To Convert Oven Burner1. Open oven door and remove oven racks, oven tray, flamespreader and set aside.2. Lift oven burner. The orifice spud is behind

Page 8

W10032050©2006 Whirlpool CorporationAll rights reserved.Printed in Mexico07/2006

Page 9 - Level Range

2You can be killed or seriously injured if you don't immediately You can be killed or seriously injured if you don'tfollow All safety messa

Page 10 - Check Operation

3WARNING: If the information in this manual is not followed exactly, a fire or explosionmay result causing property damage, personal injury or death.–

Page 11 - Complete Installation

4INSTALLATION REQUIREMENTSTools and PartsGather the required tools and parts before starting installation.Read and follow the instructions provided wi

Page 12 - GAS CONVERSIONS

Installation ClearancesCabinet opening dimensions shown are for 25" (64 cm)countertop depth, 24" (61 cm) base cabinet depth and 36" (91

Page 13 - Complete Conversion

Gas Supply RequirementsObserve all governing codes and ordinances.IMPORTANT: This installation must conform with all local codesand ordinances. In the

Page 14 - Natural Gas Conversion

7†®TEFLON is a registered trademark of E.I. Du Pont De Nemours and Company.Flexible metal appliance connector: If local codes permit, a new CSA desig

Page 15

8INSTALLATION INSTRUCTIONSUnpack Range1. Do not use oven door handle to lift or move the range. 2. Remove shipping materials, tape and protective film

Page 16 - W10032050

9Make Gas ConnectionTypical rigid pipe connectionA combination of pipe fittings must be used to connect the rangeto the existing gas line. Your connec