Tension adjustment of the door spring
The door springs are set at the factory to the proper tension for the outer door. If aesthetic wooden panel
are installed, you will have to adjust the door spring tension. Rotate the adjusting screw to drive the
adjustor to strain or relax the steel cable (see figure 5).
Door spring tension is correct when the door remains horizontal in the fully opened position yet rises to a
close with the slight lift of a finger.
Figure 5
Tension adjustment of the door spring.
relax
Connection of drain hoses
Insert the drain hose into a drain pipe with a minimum diameter of 4cm, or let it run into the sink, making
sure to avoid bending or crimping it. Use the spe ial plastic support that comes with the appliance (figure 6).
The free and of the hose must be at a height between 400 and 1000mm and must not be immersed in water
to avoid the back flow of it.
ATTENTION: The special plastic hose support must be solidly fastened to the wall to prevent the drain
hose from moving and allowing water to spill outside the drain.
Close the drain hose hook to the counter
Drain pipe
Drain hose hook
Counter
Front
Figure 6
Drain pipe connection.
ATTENTION. Please hang up the drain
hose either way of A, B or C