Whirlpool AKT 352/IX Instruction for Use Page 4

  • Download
  • Add to my manuals
  • Print
  • Page
    / 5
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 3
ELECTRICAL CONNECTION
The electrical connections must comply with local regulations.
The data relevant to the voltage and power absorption are indicated on the rating plate.
The earthing of this appliance is compulsory by law.
The manufacturer cannot be held responsible for any injury to persons or animals or damage to property
arising from failure to comply with these requirements.
When the hob is installed, provide a single-pole circuit breaker with a contact separation of at least 3 mm.
If necessary, the electrical power cable must be replaced exclusively with a power cable having identical
characteristics to the original supplied by the manufacturer (type H05V2V2-F T90°C or H05RR-F). This
operation must be performed by a qualied electrician.
L
Earth
(yellow/green)
N
2
3
1
ADJUSTMENT TO DIFFERENT TYPES OF GAS
If the appliance is intended to operate with a different gas from the gas type stated on the rating plate and orange sticker applied on the top of the hob, change
the injectors.
Remove the orange sticker and keep it with the instructions booklet.
Use pressure regulators suitable for the gas pressure indicated in the Product Description Sheet.
The gas nozzles must be changed by After Sales Service or a qualied technician.
Nozzles not supplied with the appliance must be ordered from After Sales Service.
Adjust the minimum setting of the taps.
Note: when liquid petroleum gas is used (G30/G31), the minimum gas setting screw must be tightened as far as it will go. Should you experience
difculty in turning the burners knobs, please contact the After Sales Service for thereplacement of the burner tap if found to be faulty.
REPLACING THE INJECTORS (see the injector table in the Product Description Sheet)
Remove grids (A).
Extract burners (B).
Using a socket spanner of the appropriate size unscrew the injector (C).
Replace it with the injector suitable for the new type of gas.
Before installing the hob, remember to afx the gas calibration plate supplied with the
injectors in such a way that it covers the existing information relating to gas calibration.
ADJUSTING MINIMUM GAS SETTING OF TAPS
To ensure that the minimum setting is correctly adjusted, remove the knob and proceed
as follows:
tighten the screw to reduce the height of the ame (-);
loosen the screw to increase the height of the ame (+);
The adjustment must be performed with the tap in minimum gas setting position (small
ame) .
The primary air of the burners does not need to be adjusted.
At this stage, light up the burners and turn the knobs from max position to minimum
position to check ame stability.
Upon completion of adjustment, reseal using sealing wax or an equivalent material.
Page view 3
1 2 3 4 5

Comments to this Manuals