AKT 795 PRODUCT DESCRIPTION SHEET
GB
5019 319 62000
To get full satisfaction from the hob, please read these instructions carefully and keep them for future consultation.
IT
LIGHTING THE BURNERS
To ignite one of the burners, turn the relative knob anti-clockwise to the maximum flame setting .
Press the knob against the control panel to ignite the burner.
After the burner has ignited, keep the knob pressed for about 5 seconds to allow the thermocouple to warm up.
This burner safety device shuts off the gas supply to the burner if the flame goes out accidentally (because of sudden
draught, an interruption in the gas delivery, boiling over of liquids, etc.).
The device must not be pressed for more than 15 sec. If, after that time has elapsed, the burner does not
remain lit, wait at least one minute before trying to light it again.
- The burner might go out when the knob is released. This means that the thermocouple has not warmed up enough.
In this case, repeat the operations described above.
PRATICAL ADVICE FOR USING THE BURNERS
For better burner performance, please stick to the following
rules:
- Use pots and pans that fit the burners (see table on the
right).
- Only use flat-bottomed pots and pans.
- Use the correct amount of water for cooking foods and
keep the pot covered.
1.
Removable panstand grids
2.
Auxiliary burner
3.
Semi-rapid burner
4.
Rapid burner
5.
Semi-rapid burner
6.
Ultra-rapid burner
7.
Auxiliary burner control knob
8.
Semi-rapid burner control knob
9.
Rapid burner control knob
10.
Semi-rapid burner control knob
11.
Ultra-rapid burner control knob
SYMBOLS
Tap closed
Maximum flame
Minimum flame
Burner Pot Ø
Ultra-rapid from 24 to 26 cm
Rapid from 24 to 26 cm
semi-rapid from 16 to 22 cm
auxiliary from 8 to 14 cm
DIMENSIONS AND DISTANCES TO BE MAINTAINED (mm)
NOTE:
If the distance A between the wall cabinets is between 600 mm and 730 mm,
the height B must be a minimum of 530 mm. If the distance A between the
wall cabinets is greater than the width of the cooktop, the height B must be
a minimum of 400 mm. In case of installation of a hood above the cooktop,
please refer to the hood instructions for the correct distance.
INJECTOR TABLE CATEGORY II2H3+
ELECTRIC SUPPLY: 230 V - 50 Hz
Type of gas used Type of burner Ø injector Rated thermal
flow rate kW
Rated
consumption
Reduced heat
capacity kW
Gas pressure (mbar)
min. rat. max.
NATURAL GAS
(Methane) G20
Ultra-rapid
Rapid
Semi-rapid
Auxiliary
136
128
95
78
3.50
3.00
1.65
1.00
333 l/h
286 l/h
157 l/h
95 l/h
0.60
0.60
0.35
0.30
17 20 25
LIQUID
PETROLEUM GAS
(Butane) G30
Ultra-rapid
Rapid
Semi-rapid
Auxiliary
94
87
67
50
3.50
3.00
1.65
1.00
254 g/h
218 g/h
120 g/h
73 g/h
0.60
0.60
0.35
0.30
20 28-30 35
LIQUID
PETROLEUM GAS
(Propane) G31
Ultra-rapid
Rapid
Semi-rapid
Auxiliary
94
87
67
50
3.50
3.00
1.65
1.00
250 g/h
214 g/h
118 g/h
71 g/h
0.60
0.60
0.35
0.30
25 37 45
Type of gas
used
Configuration
model
Rated thermal
flow rate kW
Total rated
consumption
Air necessary (m
3
) for the
combustion of 1 m
3
of gas
G20 20 mbar 5 burners 10.8 1028 l/h 9.52
G30 28-30 mbar 5 burners 10.8 785 g/h 30.94
G31 37 mbar 5 burners 10.8 771 g/h 23.80