Whirlpool AMB 892/G Instruction for Use

Browse online or download Instruction for Use for Split-system air conditioners Whirlpool AMB 892/G. Whirlpool AMB 892/G Instruction for Use [tr] User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 20
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
137
INSTRUCTIONS FOR USE
DUAL SPLIT AIR CONDITIONER WITH
GREEN GAS
AND WITH ECO GAS
PREPARATION BEFORE USE
SAFETY PRECAUTIONS
IDENTIFICATION OF PARTS
REMOTE CONTROL
OPERATION INSTRUCTIONS
MAINTENANCE
TROUBLESHOOTING
PROTECTION
INSTALLATION INSTRUCTIONS
ELECTRICAL CONNECTION
GREEN RANGE
ECO RANGE
This appliance is marked according to the European directive 2002/96/EC on Waste Electrical and
Electronic Equipment (WEEE).
This guideline is the frame of a European-wide validity of return and recycling on Waste Electrical
and Electronic Equipment.
33933051GB.fm Page 137 Tuesday, January 18, 2005 3:31 PM
Page view 0
1 2 3 4 5 6 ... 19 20

Summary of Contents

Page 1 - ECO RANGE

137INSTRUCTIONS FOR USEDUAL SPLIT AIR CONDITIONER WITH GREEN GAS AND WITH ECO GAS PREPARATION BEFORE USESAFETY PRECAUTIONSIDENTIFICATION OF PARTSREM

Page 2 - SAFETY PRECAUTIONS

146MAINTENANCETROUBLESHOOTINGAppliance maintenanceUnplug from the power supplyStop the appliance before unplugging.•To remove the front panel pull it

Page 3 - IDENTIFICATION OF PARTS

147PROTECTIONOperating conditionFeatures of protection deviceNoise pollutionHEATING mode featuresThe protective device may trip and stop the appliance

Page 4

148INSTALLATION INSTRUCTIONSNOTE:The figure above is only a simple presentation of the unit, it may not match the external appearance of the unit you

Page 5 - REMOTE CONTROL

149Select the best locationLocation for Installing the Indoor Unit•Where there is no obstacle near the air outlet and air can easily be blown to every

Page 6 - OPERATION INSTRUCTIONS

150Indoor unit installation1.Installing the Mounting Plate•Select a location to install the mounting plate according to the indoor unit location and p

Page 7 - Clock button

151How to Purge Air TubesThermal Insulation Piping:Place the drain hose under the piping.Insulating material: polythene foam over 6 mm in thickness.

Page 8 - Timer mode

1524.Connecting the CableIndoor UnitConnect the power cord to the indoor unit by connecting the wires to the terminals on the control board individua

Page 9 - Sleep mode

153Wiring DiagramMake sure that the colour of wires of the outdoor unit and the terminal number are the same as those of the indoor unit.Control conne

Page 10 - TROUBLESHOOTING

154Make sure that the colour of wires of the outdoor unit and the terminal number are the same as those of the indoor unit.7 K,9 K,12 K,18 K ModelFor

Page 11 - PROTECTION

155Air purgingThe air which contains moisture remaining in the refrigeration cycle may cause a malfunction on the compressor. After connecting the ind

Page 12 - INSTALLATION INSTRUCTIONS

138PREPARATION BEFORE USESAFETY PRECAUTIONSBefore using the air conditioner, be sure to check and preset the following.• Remote Control presettingThe

Page 13 - Outdoor unit installation

156ELECTRICAL CONNECTION1) For Great Britain onlyWarning - this appliance must be earthedFuse replacementIf the mains lead of this appliance is fitted

Page 14 - Indoor unit installation

139IDENTIFICATION OF PARTSIndoor unitA- Air IntakeB- Front PanelC- Operation PanelD- DisplayE- Air OutletF- Vertical Adjustment LouverG- Horizontal Ad

Page 15 - How to Purge Air Tubes

1401.Emergency buttonUsed to control the unit when the remote control is out of work. Used to set or cancel auto restart function. (See page 23)2.Run

Page 16

141REMOTE CONTROLNOTE: Each mode and relevant function will be further specified in following pages.The remote control transmits signals to the system

Page 17 - Control connecting cable

142OPERATION INSTRUCTIONSOperating modes1. Selecting modeEach time MODE button is pressed, the operation mode is changed in sequence:COOLING DRY FANON

Page 18

1436th Sense modeHorizontal airflow control (with hands)Turn the control rods of the horizontal adjustment louvers to change horizontal air flow as sh

Page 19 - Air purging

144Round U mode (available on R410a models only)When you press the Round U button the remote controller transmit signal of the actual room temperatur

Page 20 - ELECTRICAL CONNECTION

145JET mode•JET mode is used to start or stop fast cooling.Fast cooling operates at high fan speed, changing the set temperature automatically to 18°C

Comments to this Manuals

No comments