ELECTRIC DRYER ELECTRICAL CONNECTIONS (FORU.S.A. ONLY)
Connecting 3=Wire Connection: Power Supply Cord
Standard Power Cord Connectors
Flanged Spade Connector RingConnector
2. Connect neutral wire (white or center wire)) (D) of power
supply cord under center terminal block screw (A). Tighten
screw.
Connecting Neutral Wire
1. Loosen or remove center terminal block screw (A).
3. Connect remaining wires under outer terminal block screws
(F). Tighten screws. Finally, reinstall terminal block to dryer
rear panel. Secure cover with hold-down screw.
" n
1i
Connecting 4-Wire Connection: Direct Wire
IMPORTANT: A 4-wire connection is required for mobile
homes and where local codes do not permit the use of 3-wire
connections.
Direct wire cable must have 5 ft. (1.52 m) of extra length so
dryer can be moved if needed.
Strip 5" (127 mm) of outer covering from end of cable, leaving
bare ground wire at 5" (127 mm). Cut 11/2"(38 mm) from 3
remaining wires. Strip insulation back 1" (25 mm). Shape ends
of wires into a hook shape.
Connecting Neutral Ground and Neutral Wires
1. Remove center terminal block screw (A) and the neutral
ground wire (B) by removing the green external ground
conductor screw (C).