WGFM29 / WGFD29.00 www.whirlpoolcomfort.com 15
THERMOSTATS
A two-stage thermostat should be used with the WGFM29 and WGFD29 furnace. Two-stage thermostats control which
ring rate is used depending on the temperature difference between the set point and the room temperature. A properly
used two-stage thermostat and furnace will maintain a much tighter control of temperature than a conventional single-
stage thermostat and furnace. Two-stage furnaces have “W1” and “W2” terminals. If the thermostat has “Y1” and
“Y2” cooling connections and a single-stage cooling system is used, connect “Y” on the furnace control to “Y1” on
the thermostat.
STANDARD ALTITUDE INSTALLATIONS
Gas Altitude Kit Orifi ce
Manifold Pressure
Pressure Switch
Change
High Stage Low Stage
Natural      
Propane      
Notes:
For installation in Canada, gas furnaces are certifi ed only to 4,500 ft.
For ACVA installations above 7,000 ft., please refer to your Amana distributor for required kit(s).