- Manual calibration: (or upon request) is set in the
conguration menu. This procedure is advised, and may
be started, in case of malfunctioning of the sensor (which,
for example, may occur in case of blackout while cooking
or after a long time since the use).
For the manual calibration, proceed with the steps below:
with the hood OFF or in standby, the menu is accessed
by pressing the T6 and T7 buttons for a prolonged
time; this is signalled by a sound emitted by the hood
and by the I4 icon lighting up and the writing C1-0
appearing on the display;
use the buttons T6 and T7 to go through the menu.
Use T6 to go through the various menu items (C1, C2,
C3, C4, etc) and T7 to select them (0, 1 or 0, 1, 2);
for the manual calibration, access the menu, select
item C4 with T6 and set value 1 with T7. Then press
T1 and wait for the time suggested for the calibration.
Selecting the hob type: the type of hob (electric, induction,
gas) present under the hood is select upon installation. A
complete automatic calibration procedure is carried out
immediately after selecting the hob.
Important: do not force the calibration “upon
request” after selecting the hob as this activates
automatically.
To select the hob, proceed as follows:
with the hood OFF or in standby, the menu is accessed
by pressing the T6 and T7 buttons for a prolonged time;
this is signalled by a sound emitted by the hood and by
the I4 icon lighting up and the writing C1-0 appearing on
the display;
use the buttons T6 and T7 to go through the menu. Use
T6 to go through the various menu items (C1, C2, C3,
C4, etc) and T7 to select them (0, 1 or 0, 1, 2);
to select the hob, access the menu, select item C3 with
T6 and set the value with T7 to 0 if you have a gas hob,
1 if you have a radiant hob and 2 if you have an induction
hob. Press T1 to leave the menu mode and wait the time
needed for the sensor calibration.
Hood type setting
The hood can be set in the ventilation (default) and ltering
operating mode. To change the type proceed as follows:
with the hood OFF or in standby, the menu is accessed by
pressing the T4 and T5 buttons for a prolonged time; this is
signalled by a sound emitted by the hood and by the I4 icon
lighting up and the writing C1-0 appearing on the display;
use the buttons T4 and T5 to go through the menu. Use
T4 to go through the various menu items (C1, C2, C3,
C4, etc) and T5 to select them (0, 1 or 0, 1, 2);
to set the hood type, access the menu, select the item
C6 with T4 and set the value 0 with T5 to set the hood on
ventilation mode or 1 for the ltering mode. Then press T1.
Hood off
The hood can be turned off manually by pressing the T1
button (ON/OFF). If the hood stays on in manual mode, it
turns off automatically after a certain “safety” time. If the
timer is set, the hood turns off automatically when the set
time runs out.
The Automatic mode activates after 10 minutes from the
sensor turning off the hood motor.
Conguration table
Regulation
code
Meaning Explanation
C1 Grease lter timer
It resets the grease
lter timer
C2 Odour lter timer
It resets the odour lter
timer
C3 Hob type
It changes the hob type
for the AUTO sensor. It
may be gas, electric or
induction
C4 Sensor calibration
It calibrates the sensor.
If item 1 is select, the
sensor carried out the
calibration the next
time the hood is turned
on
C5 Audio levels
If mute, no FB audio is
emitted (not even when
turning ON)
C5 Hood type
Ventilation/Filtering
(Ventilation by default)
C6
Reset to Factory
default
It resets the DGT menu
values to default values
(including installation)
General notes
If the display buttons become locked, unplug and plug
in again the hood from the mains before contacting the
Assistance Service.
Maintenance and care
Caution! Before cleaning or servicing the unit,
disconnect it from the mains by pulling the power plug
or disconnecting the main circuit breaker.
First cleaning
Remove the protective lm
Clean with a damp sponge and a little neutral soap
Rinse off with a damp cloth
Dry with a soft cloth; if the hood is stainless steel, dry
along the metal's grain
Periodic cleaning
The hood must be cleaned frequently (at least as often as
you service the grease lter), inside and out. Use a damp
cloth and a neutral liquid detergent with lukewarm water.
Do not use abrasive or corrosive products.
Warning: Failure to observe the hood cleaning and lter
cleaning/replacement instructions can result in res. Follow
the instructions carefully. The manufacturer is not liable for
any damage to the motor or res caused by incorrect care
or failure to follow the above instructions.
Page view 31
1 ... 31 32 33 ... 72

Comments to this Manuals

No comments