Electrical connection
THE APPLIANCE MUST BE EARTHED
The cooktop is designed to work with alternating current at
the supply voltage and frequency indicated on the rating
plate (situated under the hob or at the end of the instruction
booklet). Make sure that the local supply voltage
corresponds to the voltage indicated on the rating plate.
The electrical cooktop is not supplied with a power supply
chord because the type of chord used depends on the type
of electrical connection (see the following connection
diagram).
Use a rubber cable of the type H05VV-F.
Open the terminal box following the instructions illustrated
in the diagram below:
To connect the supply chord, proceed as follows:
l Loosen the screws on the wire clamp “V”, as well as
the screws for the contacts.
l Insert the wires beneath the contact screws, as shown
in the diagram, and tighten them.
l Fasten the chord with the appropriate wire clamp and
close the cover.
lacirtcelE
noitcennoc
egatlovylppusrewoPesuFnoitceS
zH06/05~N+1-V032
A2mm4
zH06/05~2-V032
A2mm4
zH06/05~N+-V004
A5mm5.2
zH06/05~3-V032
A5mm5.2
zH06/05~N+3-V004
A6mm5.1
zH06/05~N2+2-V032
A5mm5.2
Connecting the supply cable to the mains
Fasten the appropriate standard plug for the load indicated
the rating plate to the chord. If the appliance must be directly
connected to the mains, a multipolar switch must be installed
between the appliance and the mains. The multipolar switch
must have a minimum of 3 mm of space between the
contacts, be sized to the load, and comply with current
regulations (the switch must not be able to disconnect the
earth conductor). The supply cord must be positioned so
that no part of it reaches a temperature of 50 °C higher
than room temperature. Before making the connection, make
sure that:
l the limiter valve and the residential wiring can support
the appliance load (see rating plate);
l the mains system is properly earthed in compliance with
current regulations and provisions;
l there is easy access to the socket or the multipolar
switch after the appliance is installed.
Attention: If the cooktop is installed above a built-in oven,
the electrical connection for the cooktop must be
independent of that for the oven, both for safety reasons
and to facilitate the removal of the oven for maintenance,
repair, etc.
1
L
2345
N
1
L1
2345
L2
1
L1 L2
2345
N
1
L1 L2 L3
2345
1
L1 L2 L3
2345
N
1
L1 L2 N1
2345
N2
2
1
1
2
3
4
5