Whirlpool Cabrio,- WED7300X Troubleshooting Guide Page 3

  • Download
  • Add to my manuals
  • Print
  • Page
    / 16
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 2
NECÈIP3EGAPB43662001W.ONTRAP
o
W10026634B
FOR SERVICE TECHNICIAN ONLY D O NOT REMOVE OR DESTROY POURLETECHNICIEN SEULEMENT NE PAS ENLEVERNIDÉTRUIRE
NOTE: Pressing SOIL LEVEL, SPIN SPEED,WATER
LEVELorLOAD SIZE, andWASH/RINSETEMPwillcause
allindicatorsabove thesebuttonstotoggleon(oroff)at
one time.
If any of the following occur during preceding steps, see
TEST #4, page 5:
None of the indicators light up
No beep sound is heard
Some buttons do not light indicators
DEACTIVATION OF DIAGNOSTIC
TEST MODE
Press the STOP, PAUSE/CANCEL, or POWER button
at any time to exit Automatic, Manual, or Console &
Indicators diagnostic test modes.
DISPLAY FAULT/ERROR CODES
Display
(Saved
Code)
EXPLANATION AND
RECOMMENDED PROCEDURE
Long Fill
LF flashes whenthewaterleveldoesnot
change foraperiodoftimeORwateris
present butcontrol does not detect thewater
levelchanging.
Is water supply connectedandturnedon?
Arehosescreensplugged?
Is water siphoning out of the drain hose?
Check for proper drainhoseinstallation.
Is thepressure hoseconnection from the tub
to the machine/motor control pinched,
kinked, pluggedorleaking air?
SeeTEST#2,page4.
Long Drain
Ld flashes whenthewaterleveldoesnot
change after the drain pump is on.
Is thedrain hoseorthedrain pump clogged?
Is the drainhoseheight greater than 96"?
Is thepressure hoseconnection from the tub
to the machine/motor control pinched,
kinked, pluggedorleaking air?
Is thepumprunning? If not, see TEST #7,
page6.
(none)
Unbalanced Load
uL is displayedwhenthemachine/motor
control detectsanoff-balanceload,andis
steady on whilethewasherrunsamini-cycle
to rebalancetheload.
Display clearsifmini-cyclesuccessfully
rebalanced theload.
If themini-cycleisunsuccessful, uL will
flash until the lid is opened,allowing the
customer to view and redistribute theload.
Overloaded
oL flashes when the machine/motor control
detects a load size that exceeds the
washer’s capacity OR basket can not
disengage. This may signify:
Load size exceeds washer capacity.Remove
excess laundry,thenrestart cycle.
Mechanicalfriction on drive mechanism,
not allowing the basket to disengage.
Display
(Saved
Code)
EXPLANATION AND
RECOMMENDED PROCEDURE
Suds Detection
Sd is displayedwhenthemachine/motor
control, by analyzing drag on the basket,
detectsasuds-lockcondition, and is steady on
while thecontrol then runs a mini-clean out
cycle.Iftheclean outcycleisunabletocorrect
theover-sudsing problem, the cycle ends and
Sd flashes in the display. This may signify:
Loadisbunchedortwistedaround agitator.
Excessive detergentusage.
Basket cannot engage during drain step.
Mechanicalfriction on drive mechanism,
not allowing basket to engage.
Open/Close Lid
lid flasheswhen thefollowing conditions
occur:
Userpresses START with lid open.
UserpressesSTARTafter2consecutive
machine cycles without opening lid.
The machine/motor control cannot detect the
lid switch opening and closing properly.
SeeTEST#8,page6.
(none)
Pump Out(lid opened)
Po flasheswhen drain pump begins pumping
out water fromtubuponactivation by the
lid having been left open for more than 10
minutes.
Close lid to stop drainpump.
(none)
Hot, Cold Reversed
HC flasheswhen the hot and cold inlethoses
arereversed.
Make sureinlet hoses are connected
correctly.
If hosesareinstalledproperly, Automatic
Temperature Control maybestuck in low
resistance range. SeeTest #5, page 5.
LidLockFailure
dL flashesifthefollowing conditions occur:
Lidisnotclosed completely due to
interference.
Check for lock interference with lid or lock
bezel.
Washmedia buildup is preventing thelock
bolt from extending.
Machine/motorcontrol detectsopenlid
switch whenattempting to lock.
Machine/motor control cannot determine if
lidlock is in a locked state.
SeeTEST#8,page6.
LidUnlockFailure
dU flashesifthefollowing conditions occur:
Excessive forceonlidispreventing lock bolt
from retracting.
Washmediabuildupispreventing lock bolt
from retracting.
Machine/motor control cannot determine if
lid lock is in an unlocked state.
SeeTEST#8,page6.
Display
(Saved
Code)
EXPLANATION AND
RECOMMENDED PROCEDURE
Pressure Signal Out-of-Range
F then 1 flasheswhen thecontrol detectsan
outofrange pressure signal.
Check pressure hose connection from tub
to machine/motorcontrol.Ishosepinched,
kinked,pluggedorleaking air?
If F then 1 repeats numerous times after
POWER is pressed and the pressure hose
connection is not pinched or kinked,
replace the machine/motor control.
Keypad/User Interface Failure
F then 2 flashes whenin:
Diagnostic Test modeifastuck keyis
detected.
Standbymodeifthere is a user interface
mismatch.
SeeTEST#4,page5.
ATCThermistorOpen/Short
F then 40 flasheswhen the ATC Thermistor is
detected to be open or shorted.
See TEST #5, page 5.
Motor RPS Thermistor Open/Short
F then 41 flasheswhen the motor rotor
position sensor (RPS) thermistorisdetectedto
be open or shorted.
See TEST #3, page 4.
NOTE: This errorcodeisonly displayed when
viewing savedfault codes.
See Diagnostic Test, page 1, for accessing
saved fault codes.
Heater in unknown state
F then 42 flasheswhen thecontrol cannot
detectiftheheaterisONorOFF.
See TEST #9, page 6.
Heater is continuously ON
F then 43 flashes when the heater is ON when
it should be OFF.
See TEST #9, page 6.
Heater cannot be turned ON
F then 44 flashes when the heater has been
turned ON by the control, but the control
cannot detect that the heater is ON.
See TEST #9, page 6.
Motor Stalled
F then 50 flasheswhen the motor rotor
position sensor (RPS) sensesnorotation.
Does basket turn freely? If not, make sure
bottomshipping packhasbeenremoved.
Determine cause of friction.
If basket turnsfreely, seeTEST#3,page4.
Motor RPS Failure
F then 51 flasheswhen thereisamotor rotor
positionsensor (RPS)failure or lower harness
problem.
See TEST #3, page 4.
Motor Stop Failure
F then 52 flasheswhen the motor rotor position
sensor (RPS) senses rotation afterStop
command.
See TEST #3, page 4.
Page view 2
1 2 3 4 ... 16

Comments to this Manuals

No comments