FOR SERVICE TECHNICIAN ONLY - DO NOT REMOVE OR DESTROY POUR LE TECHNICIEN SEULEMENT - NE PAS ENLEVER NI DÉTRUIRE
PART NO. 8558724 PAGE 7 PIÈCE N
o
8558724
Thermistor
Thermistance
Heater
chauffant
Element
Élément
Thermal Cut-Off
Coupe-circuit
thermique
High Limit Thermostat
Thermostat - limite haute
Thermal Fuse
Fusible thermique
Thermal
Components,
viewed from front.
Composants du
système de chauffage -
vue de face.
Figure 9
TEST #3 Heater Test
This test is performed when either of the
following situations occur:
Dryer doesn’t heat
Heat won’t shut off
This test checks the components making
up the heating circuit. The following items
are part of this system:
Harness/
connection
Heater relay
Thermal cut-off
High limit
thermostat
Heat element
assembly
Centrifugal switch
Thermistor
Machine control
electronics. See
ESD information,
page 1.
Console
electronics and
housing
Dryer does not heat:
1. Unplug dryer or disconnect power.
2. Remove the toe panel to access the
thermal components. See figure 14,
page 13. Locate the components using
figure 9.
3. Using an ohmmeter and referring to the
wiring diagram, measure the resistance
from the red wire at the thermal cutoff to
the red wire at the heater.
TEST N
o
3 Contrôle de l’élément
chauffant
On exécute ce test lorsque l’une des situations
suivantes se manifeste :
Absence de chauffage
Impossibilité d’arrêt du chauffage
Avec ce test, on contrôle les composants du circuit
de chauffage; il s’agit des composants suivants :
Câblage/connexion
Relais de chauffage
Coupe-circuit
thermique
Thermostat -
limite haute
Élément chauffant
Contacteur centrifuge
Thermistance
Circuit électronique
de commande de la
machine. Voir à la page
1 l’information sur la
décharge électrostatique.
Module électronique
de la console et carter
Absence de chauffage :
1. Débrancher la sécheuse ou déconnecter la source
de courant électrique.
2. Enlever le panneau de plinthe pour accéder aux
composants du système de chauffage. Voir figure
14, page 13. À l’aide de la figure 9, identifier les
composants.
3. Utiliser le schéma de câblage et un ohmmètre;
mesurer la résistance entre le conducteur rouge sur
le coupe-circuit thermique et le conducteur rouge
sur l’élément chauffant.
If the resistance is about 10 ohms, go to step 5.
If an open circuit is detected, go to step 4.
4. Visually check the wire connections to the thermal cutoff, high
limit thermostat, and heater. If connections look good, check for
continuity across each of these components. Replace the one
that is electrically open.
5. If no open circuit is detected, measure the resistance between
P2-5 (red/white wire) and P2-6 (black wire) at the machine
control board.
If 6–7 k ohms are measured, replace the machine control
electronics.
If the resistance is less than 1 k ohm, replace the thermistor.
Heat will not shut off:
1. Unplug dryer or disconnect power.
2. Access the machine control electronics, and measure the
resistance between P2-5 (red/white wire) and P2-6 (black wire).
See Accessing & Removing the Electronic Assemblies, page 13.
If 6–7 k ohms are measured, replace the machine control
electronics.
If the resistance is much greater than 7 k ohms, replace the
thermistor.
TEST #3a Thermistor Test
The machine control electronics monitors the exhaust temperature
using the thermistor, and cycles the heater relay on and off to
maintain the desired temperature.
Begin with an empty dryer and a clean lint screen.
1. Plug in dryer or reconnect power.
2. Set the following configuration:
Door – must be firmly closed
Press Control On
Press End Of Cycle Signal (Louder)
Press Start
3. If after 60 seconds, E1 or E2 flashes in the display and the dryer
shuts off, the thermistor or wire harness is either shorted or open.
Si la résistance est d’environ 10 ohms, passer à l’étape 5.
S’il y a un circuit ouvert, passer à l’étape 4.
4. Inspecter visuellement les connexions des conducteurs sur le coupe-circuit
thermique, le thermostat de température maximum et l’élément chauffant. Si
les connexions sont en bon état, contrôler la continuité à travers chacun de
ces composants. Remplacer le composant qui reste en circuit ouvert.
5. S’il n’y a aucun circuit ouvert, mesurer la résistance entre P2-5 (conducteur
rouge/blanc) et P2-6 (conducteur noir) sur la carte des circuits de commande
de la machine.
Si on mesure une résistance de 6–7 k ohms, remplacer le module de
commande électronique de la machine.
Si la résistance est inférieure à 1 k ohm, remplacer la thermistance.
Impossibilité d’arrêt du chauffage :
1. Débrancher la sécheuse ou déconnecter la source de courant électrique.
2. Accéder au module de commande électronique de la machine et mesurer la
résistance entre les points P2-5 (conducteur rouge/blanc) et P2-6
(conducteur noir). Voir la page 13 - Modules électroniques accès et dépose.
Si on mesure une résistance de 6–7 k ohms, remplacer le module de
commande électronique de la machine.
Si la résistance est bien supérieure à 7 k ohms, remplacer la
thermistance.
TEST N
o
3a Test de la thermistance
Le module de commande électronique de la machine assure un suivi de la
température dans le circuit de décharge, au moyen d’une thermistance;
l’alimentation intermittente du relais du circuit de chauffage permet de
maintenir la température désirée. Travailler sur une sécheuse vide, avec tamis
à peluches propre.
1. Brancher la sécheuse ou reconnecter la source de courant électrique.
2. Établir la configuration suivante :
Porte – parfaitement fermée
Appuyer sur Control On (module de commande en marche)
Appuyer sur End Of Cycle Signal (signal de fin de programme) (Louder)
(Plus fort)
Appuyer sur Start (mise en marche)
3. Si après 60 secondes on obtient le clignotement du code E1 ou E2 sur
l’afficheur alors que la machine s’arrête, il y a un court-circuit ou circuit ouvert
affectant la thermistance ou le câblage.