4. PROPER OPERATION OF THE DEVICE
Refrigerating devices can be exploited in a ventilated room in the following environment temperature
ranges:
refrigerator and freezer cases solid door from +16 to +43°C and relative humidity not exceeding 60%,
refrigerator and freezer cases glass door from +16 to +32°C and relative humidity not exceeding 60%,
refrigerator and freezer tables from +16 to +32°C and relative humidity not exceeding 60%,
To assure the best working conditions for the device, the user should locate the device in the coldest place
of the room. The device should not be exposed to direct operation of sunlight, precipitation; it should not
be located near heat sources (heaters, heating walls, etc.).
It is recommended to:
have a proper ventilation in the room,
have a minimum 50 centimeters clearance between highest point of device and ceiling of the
room,
place the refrigeration device at least 10 centimeters from the wall of the room.
Device in operation generates heat, to enable its dissipation air circulation and ventilation should be
provided.
Installation of the device in the room not meeting the above requirements voids warranty.
Refrigeration devices are equipped with electronic controllers, providing optimal utilization of properties
of the given type of device. The producer programs the controllers based on thorough type research held
and opinions of the users. Still, there are occurrences when it is necessary to reprogram the controller
based on individual user requirements, like for example room humidity too high or very intensive rotation
of products. Such cases are to be agreed with the producer before the purchase of the device. Controller
settings are divided into two groups:
- accessible for user
- accessible for service (change of these parameters can be performed only by consent of the producer).
The operation of the device is fully automated. The producer sets the parameters of electronic thermostat
in a way to provide the user with possibility to regulate the temperature range of the interior (regulated by
the user), as well as effective evaporator defrosting and condensate removal. The way of setting of the
desired temperature is given in the appendix to the present instruction, for the used temperature regulator,
respectively. Eventual change of system parameters accessible for service can be performed only by
consent of the producer.
All controllers used by the producer have the option of manual defrosting available to user, if there is a
need of additional defrosting of the evaporator caused by hard operation conditions of the device. The
behavior of the device is the same with manual and automatic defrosting.
Page view 4