LIGHTING THE BURNERS
• To ignite one of the burners, turn the relative knob anti-clockwise to the maximum flame setting .
• Press the knob against the control panel to ignite the burner.
• After the burner has ignited, keep the knob pressed for about 5 seconds to allow the thermocouple to warm up.
This safety device shuts off the gas if the flame goes out accidentally (draughts, interruption of gas, liquids boiling over,
etc.).
• The device must not be pressed for more than 15 sec. If, after that time has elapsed, the burner does not
remain lit, wait at least one minute before trying to light it again.
- The burner might go out when the knob is released. This means that the thermocouple has not warmed up enough.
In this case, repeat the operations described above.
PRATICAL ADVICE FOR USING THE BURNERS
For optimum burner performance, observe the following
rules:
- Use pots and pans that fit the burners
(see table on the right).
- Only use flat-bottomed pots and pans.
- Use the correct amount of water for cooking foods and
keep the pot covered.
1
2
3
1. Removable grid(s)
2. 4 crowns burner
3. 4 crowns burner control knob
SYMBOLS
tap closed
Maximum flame
Minimum flame
Burner Pot Ø
4 crowns burner from 24 to 26 cm
DIMENSIONS AND DISTANCES TO BE MAINTAINED (mm)
NOTE: In case of installation of a hood above the cooktop, please refer to the hood instructions for the correct
distance.
INJECTORS TABLE CATEGORY II2L3B/P
ELECTRIC SUPPLY: 230 V ~ 50 Hz
Ty p e o f g a s u sed Ty p e o f
burner
Injector
marking
Nominal heating
capacity
kW
Nominal
consumption
Reduced heating
capacity
kW
Gas pressure (mbar)
min. nom. max.
NATURAL GAS
(Methane) G25
4 crowns 142 3.50 389 l/h 1.70 20 25 30
LIQUEFIED
PETROLEUM GAS
(Butane) G30
(Propane) G31
4 crowns 90 3.20 233 g/h 1.55 25 30 35
Type of gas used Model configuration
1 burner
Nominal heating capacity
kW
Total nominal
consumption
Air necessary (m
3
) for the
combustion of 1 m
3
of gas
G25 25 mbar 4 crowns 3.50 389 l/h 8.187
G30/G31 30 mbar 4 crowns 3.20 233 g/h 30.94