PRODUCT MODEL NUMBERS PRODUCT DIMENSIONS
GW397LXU GW399LXU
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
Ref. W10526075A
3/19/13
30" Slide-in Gas Range
CABINET DIMENSIONS
COUNTERTOP PREPERATION
The cooktop sides of the slide-in range fit over the cutout edge of your
countertop.
If you have a square finish (flat) countertop and the opening width is 30"
(76.2 cm), no countertop preparation is required.
Formed front-edged countertops: Must have molded edge shaved flat ³⁄₈"
(1.0 cm) from each front corner of opening.
Tile countertops may need trim cut back ³⁄₈" (1.0 cm) from each front
corner and/or rounded edge flattened.
If countertop opening width is greater than 30" (76.2 cm), adjust the ³⁄₈"
(1.0 cm) dimension.
Countertop must be level. Place level on countertop, first side to side;
then front to back. If countertop is not level, range will not be level. Oven
must be level for satisfactory baking conditions.
30³⁄₄" (78.1 cm)
³⁄₈"
(1.0 cm)
30"
(76.2 cm)
opening
width
A.
30³⁄₄
" (78.1 cm)
B. 35
³⁄₄
" (90.8 cm) height to underside
of cooktop edge with leveling legs
screwed all the way in*
C. Model/serial rating plate (located
behind the storage drawer on the
right-hand side of the oven frame)
D. 29
⁷⁄₈
" (75.9 cm)
E. 28
⁵⁄₁₆
" (71.9 cm) from
handle to back of range*
*
F. 2 3
³⁄₄
" (60.3 cm)
countertop notch to rear
of cooktop
C
B*
A
D
E**
F
** Range can be raised approximately 1" (2.5 cm) by adjusting the leveling legs.
** When installed in a 24" (61.0 cm) base cabinet with 25" (63.5 cm) countertop;
front of oven door protrudes 2
¹⁄₂" (6.4 cm) beyond 24" (61.0 cm) base cabinet.
Cabinet opening dimensions shown are for 25" (64.0 cm) countertop depth, 24"
(61.0 cm) base cabinet depth and 36" (91.4 cm) countertop height.
IMPORTANT: If installing a range hood or microwave hood combination above the
range, follow the range hood or microwave hood combination installation instructions
for dimensional clearances above the cooktop surface.
Range may be installed with zero clearance to combustible construction at the rear and
on the sides below the cooktop.
NOTE: 24" (61.0 cm) minimum when bottom of wood or metal cabinet is shielded by
not less than ¹⁄₄" (0.64 cm) flame retardant millboard covered with not less than No. 28
MSG sheet steel, 0.015" (0.4 mm) stainless steel, 0.024" (0.6 mm) aluminum or 0.020"
(0.5 mm) copper.
30" (76.2 cm) minimum clearance between the top of the cooking platform and the
bottom of an uncovered wood or metal cabinet.
A. 13" (33.0 cm) upper cabinet depth
B. 30" (76.2 cm) min. opening width
C. For minimum clearance to the top of the cooktop, see NOTE.
D. 23
¹⁄₄
" (59.1 cm) opening depth
E. 30" (76.2 cm) min. opening width
F. Electrical and gas supply - 5½" (14.0 cm) min. from either cabinet,
10" (25.4 cm) max. from floor. Nothing located in shaded area can
extend more than 2¼" (5.7 cm) from back wall or range will not slide
all the way back. Grounded outlet must be flush mounted.
G. Cabinet door or hinge should not extend into cutout.
H. 18" (45.7 cm)
I. 3" (7.6 cm) min. clearance from both sides of the range to the side
wall or other combustible material.
Gas supply: Use ³⁄₄" rigid pipe gas supply line to the range location. A
smaller size pipe on long runs may result in insufficient gas supply. With
L.P. gas, piping or tubing size can be ¹⁄₂" minimum. If local codes permit, it
is recommended that new flexible metal tubing, design-certified by AGA or
CSA, ¹⁄₂" or ³⁄₄" I.D., be used for connecting the range to the rigid gas
supply line. A ¹⁄₂" male pipe thread is needed for connection to pressure
regulator female pipe threads. An individual manual shutoff valve must be
located in the same room, but external to the range.
Electrical:
A 120 volt, 60 Hz., AC only, 15-amp fused, electrical circuit is required. A
time-delay fuse or circuit breaker is also recommended. It is
recommended that a separate circuit serving only this range be provided.
Electronic ignition systems operate within wide voltage limits, but proper
grounding and polarity are necessary. Check that the outlet provides
120-volt power and is correctly grounded.