Whirlpool ADN 240 Instruction for Use Page 8

  • Download
  • Add to my manuals
  • Print
  • Page
    / 34
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 7
6
ENGLISH
GB
i All maintenance interventions that require
precise technical skill or particular ability must be
performed exclusively by qualified staff.
! When using the appliance, never obstruct the
air inlet when the appliance is on, so as not to
compromise its performance and safety.
! Never stretch the power cable.
In order to guarantee hygiene and protect the
foodstuffs from contamination, the elements that
come into direct or indirect contact with the
foodstuffs must be cleaned very well along with
the surrounding areas. These operations must
only be performed using detergents that can be
used with foodstuffs, avoiding inflammable
products or those that contain substances that are
harmful to personal health.
In the case of prolonged inactivity, as well as
disconnecting all the supply lines, it is necessary
to accurately clean all internal and external parts
of the appliance.
4.1. Safety Devices
During the running of appliance, some control
devices may activate and govern the correct
running of the machine. In other cases, they may
deactivate parts or the whole machine, to put the
appliance in safe conditions. Main controls are
described below.
Door micro switch
If the door is opened, the
magnetic switch placed on the control board
opens and, during blast-chilling or shock-freezing,
evaporator fans go off and a warning message
appears on the display at the same time. This
condition may also be determined when the door
is not perfectly aligned to or near the control
board: in this case with machine in STOP phase,
cycle start-up is prevented, apart from start-up of
the defrosting cycle.
Protective Fuses
Some protection fuses in the general power
supply line are activated in case of overload.
High condensation temperature alarm
In the event of room
conditions or functional failures, which cause the
condenser to exceed the maximum temperature
value, an alarm is triggered and stops the
machine running. The machine can be run when
an acceptable temperature value is reset.
Evaporator Fan Micro switch
If the deflector is opened to
inspect the evaporator or fans this micro switch
positioned on the evaporator deflector deactivates
machine functioning. Closure of the deflector with
the successive disappearance of the alarm on the
display, restores normal machine functioning.