INSTALLATION INSTRUCTIONS
Tools and Parts
Tools Needed
Gather the required tools and parts before starting installation.
Read and follow the instructions provided with any tools
listed here.
Parts Supplied (not shown to scale
Location Requirements
The microwave oven may be installed over a built-in oven. If
installing over a built-in oven, make sure there is a minimum of 3"
(7.6 cm) between the top of the lower oven cutout and the
microwave oven cutout floor.
The microwave oven may also be installed in a cabinet by itself
(without a built-in oven below). For best usability, we recommend
a minimum distance of 36" (91.4 cm) from the floor to the cutout
floor.
Make sure the surrounding cabinetry has clearance to open and
close freely. Allow a clearance of at least 1⁹⁄₁₆" (4.0 cm) below the
cutout floor (3" [7.6 cm] for installation above a built-in oven), and
a clearance of at least 2" (5.1 cm) above the cutout opening.
Required Cutout Dimensions
NOTES:
■ Depth requirements depend upon receptacle and its location
within or outside of recommended region. See illustration and
chart above.
■ Height dimension is critical: 17" (43.2 cm) minimum, 17¹⁄₈"
(43.5 cm) maximum.
■ Width measurement has ±1/16" (2 mm) tolerance.
■ 3" (7.6 cm) minimum dimension is from lower oven cutout
ceiling to microwave oven cutout floor.
■ Trim kit frame extends 1¹⁄₁₆" (2.7 cm) above and below the
cutout opening.
Trim Kit Frame Dimensions
*27" (68.6 cm) trim kit
**30" (76.2 cm) trim kit
■ Measuring tape
■ Pencil
■ Phillips screwdriver
■ Drill
■ 7/64" drill bit
Rear duct Bottom duct Rails (2)
Short screws (19)
(16 + 3 extra)
Long wood screws
(6 - painted) (4 + 2 extra)
Trim kit frame
A. Upper cabinet
B. Microwave oven cutout
C. Lower oven cutout
D. Lower cabinets
E. Floor
3"
(7.6 cm)
B
B
D
36"
(91.4 cm)
C
2"
(5.1 cm)
2"
(5.1 cm)
1⁹⁄₁₆"
(4.0 cm)
A
E
A. Trim kit frame overhang
B. Cutout for lower oven
C. Recommended region for receptacle
location (no less than 7" [17.8 cm] to
the right of cutout centerline)
D. Cutout centerline
Receptacle Location Minimum Depth
Within recommended
region
20" (50.8 cm) with flush receptacle;
22" (55.9 cm) with non-flush receptacle
Outside recommended
region
22" (55.9 cm) with flush receptacle;
24" (61.0 cm) with non-flush receptacle
3"
(7.6 cm
)
7"
(17.8 cm)
A
1¹⁄₁₆"
(2.7 cm)
1¹⁄₁₆"
(2.7 cm)
B
CD
23¹⁄₈" (58.7 cm)
17¹⁄₈" (43.5 cm)
max.
17" (43.2 cm)
min.
For minimum depth requirements, see chart.
26⁷⁄₈" (68.2 cm)**
29
³⁄₄" (75.6 cm)**
2¹⁄₁₆" (5.2 cm)*
*
3¹⁄₂" (8.9 cm)**
22³⁄₄" (57.8 cm)
12¹⁄₄
"
(31.1 cm
)
1³⁄₁₆" (3.0 cm)
19¹⁄₈"
(48.6 cm)
3⁷⁄₁₆"
(8.7 cm)