TIMER CONTACT POSITIONS
Introduction
The purpose of the timer sequence (Esterline) chart is to indicate the position of the timer contacts
during the different events of the cycles. This chart indicates the path of current flow through the
appliance at any given time. In order to interpret the timer sequence chart, it is important to understand
how it interacts with a wiring diagram.
Switch Positions
A solid black bar means that the switch is closed. No bar, or a white space, means that the switch is
open. A switch can be open or closed for part of an interval. This is indicated by a black bar for only
part of the interval space. An X means that at that point in the timer, the switch could either be open or
closed. This typically happens when a switch is either about to open or close, but since it takes some
time for that action to occur, the switch position cannot be predicted at that time.
INTERVAL LINE
SWITCH CLOSED
SWITCH CLOSED FOR
PART OF AN INTERVAL
SWITCH OPEN