To avoid possible corrosion of the heat exchanger, do not
locate the unit in an area where the outdoor air (for example,
combustion air for the unit) will be frequently contaminated by
compounds containing chlorine or fluorine. Common sources
of such compounds include swimming pool chemicals and
chlorine bleaches, paint stripper, adhesives, paints,
varnishes, sealers, waxes (which are not yet dried) and
solvents used during construction and remodeling. Various
commercial and industrial processes may also be sources of
chlorine/fluorine compounds.
To avoid possible illness or death of the building occupants,
do not locate outside air intake device (economizer, manual
fresh air intake, motorized fresh air intake) too close to an
exhaust outlet, gas vent termination or plumbing vent outlet.
For specific distances required, consult local codes.
Allow minimum clearances from the enclosure for fire
protection, proper operation, and service access. These
clearances must be permanently maintained.
The combustion air inlet and flue outlet hoods on the unit
must never be obstructed. If used, do not allow the
economizer/manual fresh air damper/ motorized fresh air
damper to become blocked by snow or debris. In some
climates or locations, it may be necessary to elevate the unit
to avoid these problems.
When the unit is heating, the temperature of the return air
entering the unit must be between 50°F and 100°F (10ºC and
38ºC).
Ground Level Installations Only
When the unit is installed on the ground adjacent to the
building, a level concrete (or equal) base is recommended.
Prepare a base that is 3" (7.6 cm) larger than the package unit
footprint and a minimum of 3" (7.6 cm) thick.
The base should also be located where no runoff of water
from higher ground can collect in the unit.
Ground Level Installation
Rooftop Installations Only
NOTE: To ensure proper condensate drainage, unit must be
installed in a level position.
To avoid possible property damage or personal injury, the
roof must have sufficient structural strength to carry the
weight of the unit(s) and snow or water loads as required by
local codes. Consult a structural engineer to determine the
weight capabilities of the roof.
Rooftop Installation
The unit may be installed directly on wood floors or on Class
A, Class B, or Class C roof covering material.
To avoid possible personal injury, a safe, flat surface for
service personnel should be provided.
Roof Curb Installations Only
Sufficient structural support must be determined prior to
locating and mounting the curb and package unit.
Ductwork must be constructed using industry guidelines. The
ductwork must be placed into the roof curb before mounting
the package unit.
Curb insulation, cant strips, flashing and general roofing
material are furnished by the contractor.
Roof Curb Installation