Top view
3. Check that air conditioner cabinet is tilted to the outside so
that water will run to the outside. If cabinet is not properly
positioned, reposition or shim cabinet to provide the proper
tilt.
4. Use a ³⁄₃₂ in. drill bit to drill starter holes through the holes in
the top channel into the window sash.
5. Attach top channel to the window with 2 - #8 x ³⁄₄ in. round-
head screws.
Complete Installation
1. Place window-lock bracket on top of lower window and
against upper window sash.
2. Use a ³⁄₃₂ in. drill bit to drill a starter hole through the hole in
the bracket into the window sash.
3. Attach window-lock bracket to window sash with #8 x ³⁄₄ in.
round-head screw to secure window in place.
4. Insert foam seal behind the top of the lower window sash and
against the glass of the upper window.
5. Plug into a grounded 3 prong outlet.
1. Side curtain against window channel
2. Window channel
3. #8 x
³⁄₄
in. round-head screw
1. #8 x
³⁄₄
in. round-head screws
3
1
2
1
1. Upper window sash
2. Window-lock bracket
1. Lower window sash
2. Foam seal
1
2
1
2
WARNING
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Failure to follow these instructions can result in
death, fire, or electrical shock.
Do not use an extension cord.
Do not use an adapter.
Do not remove ground prong.