TECHNICAL DATA
MODEL
COOLING
WATER
USAGE
L/HOUR (1)
ICE
PRODUCTION
WATER
USAGE
L/HOUR (1)
TOTAL
WATER
USAGE
L/HOUR (1)
NET
WEIGHT
(KG)
DIMENSIONS
CRATED
X*Y*Z
GROSS
WEIGHT
(KG)
VOLUME
(M
3
)
WHP AGS 836
4 4 36 490x595x765 41 0.22
WHP AGS 837
15 4 19 36 490x595x765 41 0.22
WHP AGS 838
4 4 39 490x595x830 44 0.24
WHP AGS 839
15 4 19 39 490x595x830 44 0.24
WHP AGS 840
5 5 42 490x595x960 46 0.28
WHP AGS 841
25 5 30 42 490x595x960 46 0.28
WHP AGS 842
7 7 48 610x640x960 56 0.37
WHP AGS 843
33 7 40 48 610x640x960 56 0.37
WHP AGS 844
6 6 55 690x640x1080 66 0.47
WHP AGS 845
35 6 41 55 690x640x1080 66 0.47
WHP AGS 846
23 8 60 770x640x1080 74 0.53
WHP AGS 847
45 23 68 60 770x640x1080 74 0.53
WHP AGS 848
11 12 80 940x640x1080 95 0.65
WHP AGS 849
53 11 64 80 940x640x1080 95 0.65
WHP AGS 850
11 11 98 900*650*1200 113 0.702
WHP AGS 851
70 11 81 98 900*650*1200 113 0.702
MODEL REFRIG.
CHARGE
HIGH PRESSURE LOW
PRESSURE
TOTAL
CURR.
FUSES
COMPRESSOR
OUTPUT
TOTAL
OUTPUT
MÍNIMUM MAXIMUM AVERAGE (2) (1) (2)
(GR)
Kg/cm
2
Psi
Kg/cm
2
Psi
Kg/cm
2
Psi (A) (A) (W) (W)
WHP AGS 836
260 16
228
17
240
2.5
38
1.5 10 175 220
WHP AGS 837
190 16
228
17
240
2.5
38
1.5 10 175 220
WHP AGS 838
260 16
228
17
240
2.5
38
1.5 10 190 220
WHP AGS 839
190 16
228
17
240
2.5
38
1.5 10 190 220
WHP AGS 840
270 16
228
17
240
2.5
38
1.7 10 190 270
WHP AGS 841
205/195 16
228
17
240
2.5
38
1.7 10 190 270
WHP AGS 842
270 16
228
17
240
2.5
38
2 10 210 300
WHP AGS 843
290 16
228
17
240
2.5
38
2 10 210 300
WHP AGS 844
370/390 16
228
17
240
2.5
38
2.2 10 210 310
WHP AGS 845
370 16
228
17
240
2.5
38
2.2 10 210 310
WHP AGS 846
370/380 16
228
17
240
2.5
38
2.8 10 365 450
WHP AGS 847
360 16
228
17
240
2.5
38
2.8 10 365 450
WHP AGS 848
425 16
228
17
240
2.5
38
3 10 440 500
WHP AGS 849
425 16
228
17
240
2.5
38
3 10 440 500
WHP AGS 850
400 16
228
17
240
2.5
38
6 10 440 1000
WHP AGS 851
340 16
228
17
240
2.5
38
6 10 440 1000
1) Data obtained at room temperature (20°C), water introduced at 15°C; water quality = 500ppm
2) Maximum consumption obtained at room temperature = 43°, according to UNE climate classification Class T
(Tropicalised).
NOTE: Expansion controlled by capillary.