RESIDENTIAL ELECTRIC WATER HEATER
SERVICE HANDBOOK
--------------------------------------------------------------------------------------------------------------------------------------------
Technical Training Department 23 of 36 Residential Electric Svc Handbook
Ashland City, Tennessee ©2004 STC082
Complaint: Lack of Hot Water
Test Condition: Upper thermostat satisfied
Test between upper high limit 4 and upper thermostat 4
If … … then
proper voltage is not present Replace upper thermostat.
proper voltage is present Continue to next step.
Test between lower high limit 2 and upper thermostat 4
If … … then
proper voltage is not present Push lower high limit reset. Check time clock or off
peak meter.
pushing reset restored voltage Conduct lower element checks
pushing reset did not restore voltage Replace lower high limit
proper voltage is present
Test between the terminals of the lower element
If … … then
proper voltage is not present: Check wire connections to lower controls.
proper voltage is present: Conduct grounded element checks.