Tension adjustment of the door spring
The door springs are set at the factory to the proper tension for the outer door.
If aesthetic wooden panel are installed, you will have to adjust the door spring tension.
Rotate the adjusting screw to drive the adjustor to strain or relax the steel cable (see figure 5).
Figure 5
Tension adjustment of the door spring.
Connection of drain hoses
Insert the drain hose into a drain pipe with a minimum diameter of 40mm, or let it run into the sink, making
sure to avoid bending or crimping it. The top of the hose must be less than 1000mm.
NOTE
The top of the hose must be
less than 1000mm.
Drain pipe
Counter
Front
PLEASE HANG UP THE DRAIN HOSE EITHER WAY OF A, B
Figure 6