Whirlpool Commercial Dryer Service Manual Page 5

  • Download
  • Add to my manuals
  • Print
  • Page
    / 8
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 4
ELECTRIC DRYER MODELS
(1 *I
(2.1
(3.)
Remove the terminal block cover.
Connect the neutral wire of the power supply
cord to the center silver colored terminal of the
terminal block and connect the other wires to
the outer terminals. (See Figure 10). For
connecting plainend field wire. (See Figure 15).
Replace terminal block cover.
EXTERNAL GROUND
CONNECTOR yx=~
CENTER
SILVER
COLORED
TERMINAL
BLOCK
SCREW
COPPER
POWER SUPPLY CORD
FIGURE
10
B.
If local codes DO NOT permit frame grounding to
the neutral wire of the power cord supply cord:
(1) Remove terminal block cover.
(2) Remove the ground wire (green) from the
external ground connector and fasten under
center silver colored terminal block screw.
(3) Connect the neutral wire of the power supply
cord to the center silver colored terminal of the
terminal block and connect the other wires to
the outer terminals. (See Figure 11). For
connecting plainend field wire (See Figure
15).
CONNECT SEPARATE COPPER GROUND WIRE
FROM EXTERNAL GROUND CONNECTOR
TO APPROVED GROUND
COPPER
- POWtli SUPPLY CORD
-- -- _..--. -.
(WITH STRAIN RELIEF)
- 30 AMPERES)
GROUND WIR
(GREENI
NEUTRAL
(WHITE OR
CENTER)
TO FUSED DISCONNECT
BOX OR APPROVED
WIRING DEVICE FOR
&WER SUPPLY CORD
UNGROUNDEDNEUTRAL
FIGURE 11
(4) Connect a separate copper ground wire (# 10
minimum) to a grounded cold water pipe* by
means of a clamp and then to the frame of the
appliance at the external ground connector.
Use Part# 685463 ground wire and clamp
assembly. Do not ground to a gas supply pipe
or hot water pipe. Do not connect the power
supply cord to electric power supply until
appliance is permanently grounded. (See
Figure 12).
(5) Replace terminal block cover.
groundlng clamp
must contact plpe.
FIGURE 12
*Grounded cold water pipe must have metal continuity
to electrical ground and not be interrupted by plastic,
rubber or electrically insulating connectors (including
water meter or pump) without adding a jumper wire at
these connections. (See Figure 13).
FIGURE 13
C. If connecting to a four-wire electrical system (mobile
home):
(1) Remove terminal block cover.
(2) Remove the ground wire (green) from the
external ground connector and fasten under
center silver colored terminal block screw.
(3) Connect the ground wire (green) of the power
supply cord to the external ground connector.
(4) Connect the neutral wire (white) of the power
supply cord to the center silver colored terminal
of the terminal block and connect the other wires
to the outer terminals. (See Figure 14). For
connecting plain-end field wire, (See Figure 15).
(5) Replace terminal block cover.
EXTERNAL GROUND CONNECTOR
\ ‘i\
GREEN WIRE OF HARNESS
GREEN WIRE
OF POWER
CENTER SILVER
OLORED TERMINAL
BLOCK SCREW
NEUTRAL
TO FUSED DIS-
(WHITE 0R
CONNECTBOX
CENTER)
OR APPROVED
COPPER
WIRING DEVICE
FOUR WIRE POWER
FOR POWER
\SUPPLY CORD (WITH
SUPPLY CORD
STRAIN RELIEF)
(30 AMPERES)
WIRE UNGROUNDED NEUTRAL
FIGURE 14
Page view 4
1 2 3 4 5 6 7 8

Comments to this Manuals

No comments