45
■ Induced draft
blower runs
continuously
with no further
furnace
operation.
■ Integrated
control module
LED display
provides “E2”
error code.
E2
■ Low-stage
pressure switch
circuit is not
closed.
■ Pressure switch
hose blocked,
pinched or
connected
improperly.
■ Blocked flue and/or
inlet air pipe,
blocked drain
system or weak
induced draft
blower.
■ Incorrect pressure
switch setpoint or
malfunctioning
switch contacts.
■ Loose or
improperly
connected wiring.
■ Inspect pressure
switch hose. Repair/
replace, if necessary,
■ Inspect flue and/or
inlet air piping for
blockage, proper
length, elbows and
termination.
■ Check drain system.
Correct as necessary.
■ Check induced draft
blower performance.
Correct as necessary.
■ Correct pressure
switch setpoint or
contact motion.
■ Tighten or correct
wiring connection.
■ Turn off power prior to
repair.
■ Replace pressure
switch with correct
replacement part.
■ Replace induced draft
blower with correct
replacement part.
■ Circulator
blower runs
continuously.
No furnace
operation.
■ Integrated
control module
LED display
provides “E3”
error code.
E3
■ Primary limit or
auxiliary limit
circuit is open.
■ Rollout limit
circuit is open.
■ Insufficient
conditioned air
over the heat
exchanger.
Blocked filters,
restrictive
ductwork, improper
circulator blower
speed, or failed
circulator blower.
■ Flame rollout.
■ Misaligned
burners, blocked
flue and/or air inlet
pipe or failed
induced draft
blower.
■ Loose or
improperly
connected wiring.
■ Check filters and
ductwork for blockage.
Clean filters or remove
obstruction.
■ Check circulator
blower speed and
performance. Correct
speed or replace
blower if necessary.
■ Check burners for
proper alignment.
■ Check flue and air inlet
piping for blockage,
proper length, elbows
and termination.
Correct as necessary.
■ Check induced draft
blower for proper
performance. Replace,
if necessary.
■ Tighten or correct
wiring connection.
■ Turn off power prior to
repair.
■ See Specification
Sheet applicable to
your model for
allowable rise range
and proper circulator
speed.
■ See “Vent/Flue Pipe”
section for piping
details.
■ Induced draft
blower and
circulator
blower runs
continuously.
No furnace
operation.
■ Integrated
control module
LED display
provides “E4”
error code.
E4
■ Flame sensed
with no call for
heat.
■ Short to ground in
flame sense circuit.
■ Lingering burner
flame.
■ Slow closing gas
control valve.
■ Correct short at flame
sensor or in flame
sensor wiring.
■ Check for lingering
flame.
■ Verify proper operation
of gas control valve
■ Turn off power prior to
repair.
■ No furnace
operation.
■ Integrated
control module
LED display
provides “E5”
error code.
E5
■ Open fuse. ■ Short in low voltage
wiring.
■ Locate and correct
short in low voltage
wiring.
■ Turn off power prior to
repair.
■ Replace fuse with 3A
automotive fuse.
Symptoms of
Abnormal
Operation
Diagnostic/
Staus LED
Code Fault Description Possible Causes Corrective Actions Notes and Cautions