DÅTID HGA5K HOB INSTRUCTIONS Destination
GB
To get full satisfaction from the hob, please read these instructions carefully and keep them for future consultation.
5019 619 01317/B
UKPT
ES
IT
HB 630
HOB DIMENSIONS (mm)
Operation of burners with safety device and electric ignition
To light one of the burners:
• Press the relative knob and turn it anti-clockwise to the
large flame and star setting .
• At the same time, hold the knob down until the burner
ignites.
• After the burner has ignited, keep the knob pressed
down for about 10 seconds.
• Release the knob.
If the burner does not ignite, repeat the operations described
above.
Note:
- Should particular local conditions of the delivered gas
make ignition of the burner difficult, it is advisable to
repeat the operation with the knob turned to the small
flame setting .
- The burner safety device shuts off the gas supply to the
burner if the flame goes out accidentally (because of a
sudden draught, an interruption in the gas delivery, boiling
over of liquids, etc.).
- The separator panel, positioned beneath the cooktop at a
minimum distance of 20 mm, must be sealed.
The burner safety system serves to prevent the emission of
gas if the flame should be extinguished accidentally (draughts,
interruptions in gas supply, dousing with liquids, etc.).
NOTES: In case of installation of a hood above the cooktop, please refer to the hood instructions for
the correct distance.
1. Removable panstand grids
2-5. Semirapid burners
3. Rapid burner
4. Auxiliary burner
6. Triple crown burner
7. Auxiliary burner control knob
8. Rapid burner control knob
9. Triple burner control knob
10. Semirapid burner control knob
11. Semirapid burner control knob
Symbols
Shaded circle Tap closed
Large flame
and star
Maximum opening/delivery
and electric ignition
Small flame
Minimum opening or
reduced delivery
INJECTORS TABLE CATEGORY II2H3+
ELECTRIC SUPPLY: 230V ~ 50Hz
BEFORE USING THE COOKTOP
These instructions are only valid for above mentioned
Country destinations and also on the appliance.
• Keep the packaging material (plastic bags, polystyrene
parts, etc.) out of the reach of children, as they are
potentially dangerous.
• Use a proprietary detergent to clean the stainless steel hob
and remove any grease and food deposits. Before using the
hob, be sure to remove any adhesive labels.
• Check whether the cooktop has been damaged during
transport.
• Ensure that the installation and gas/electrical
connections are performed by a qualified technician,
following the manufacturer's instructions and in
compliance with current local safety regulations.
SUGGESTIONS FOR ENVIRONMENT PROTECTION
Packing
The packaging material is 100% recyclable and marked with
the recycling symbol ( ).
Products
This appliance is marked according to the European directive
2002/96/EC on Waste Electrical and Electronic Equipment
(WEEE). By ensuring this product is disposed of correctly, you
will help prevent potential negative consequences for the
environment and human health.
The symbol on the appliance or accompanying
documentation indicates that this product should not be
disposed of as unsorted municipal waste but must be taken to
a collection point for the treatment of WEEE. Dispose of in
accordance with local standards governing waste disposal.
For further information on the treatment, recovery and
recycling of this appliance, contact your competent local
authority, the collection service for household waste or the
shop where you purchased the appliance.
Type of gas used Type of
burner
Injector
marking
Rated heat
capacity kW
Rated
consumption
Reduced heat
capacity kW
Gas pressure
(
mbar)
min. nom. max.
NATURAL GAS
(Methane) G20
triple crown
rapid
semirapid
auxiliary
132
Y 115
H2 98
X 72
3.30
3.00
1.65
1.00
314 l/h
286 l/h
157 l/h
95 l/h
1.55
0.60
0.35
0.30
17 20 25
LIQUID PETRO-
LEUM GAS
(Butane) G30
triple crown
rapid
semirapid
auxiliary
92
87
65
50
3.30
3.00
1.65
1.00
240 g/h
218 g/h
120 g/h
73 g/h
1.55
0.60
0.35
0.30
20 28-30 35
LIQUID PETRO-
LEUM GAS
(Propane) G31
triple crown
rapid
semirapid
auxiliary
92
87
65
50
3.30
3.00
1.65
1.00
236 g/h
214 g/h
118 g/h
71 g/h
1.55
0.60
0.35
0.30
25 37 45
Type of gas used
Appliance model
5 burners
Total rated heat
capacity kW
Total rated
consumption
Air necessary (m
3
) for the
combustion of 1 m
3
of gas
G20 20 mbar 3C - 1 R - 2 SR - 1 AUX 10.60 1009 l/h 9.52
G30 28-30 mbar 3C - 1 R - 2 SR - 1 AUX 10.60 771 g/h 30.94
G31 37 mbar 3C - 1 R - 2 SR - 1 AUX 10.60 757 g/h 23.80