Electrical Requirements
Continued
115-volt models with amperes
up through 7.5
Outlet wiring
Outlet wiring should be a minimum of
14 gauge. Use copper wire only. It is the
responsibility of the consumer to provide
proper and adequate receptacle wiring,
installed by a qualified electrician. Observe
National Electrical Code and all local governing
codes and ordinances.
Electrical requirements
A 115-volt (103.5 min., 126.5 max.), 60-Hz,
AC-only, 15-ampere fused electrical supply is
required (time delay fuse or time delay circuit
breaker required). It is required that a separate
circuit, serving only this air conditioner, be
provided.
Electrical connection
Electrical ground is required on this air conditioner.
Recommended ground method
For your personal safety, this air conditioner must
be grounded. This air conditioner is equipped
with a power supply cord having a 3-prong
ground plug. To minimize possible shock hazard,
the cord must be plugged into a mating 3-prong
ground-type outlet, grounded in accordance with
the National Electrical Code (ANSI/NFPA 70
latest edition) and local codes and ordinances. If
a mating outlet is not available, it is the responsi-
bility of the customer to have a properly grounded
3-prong outlet installed by a qualified electrician.
Ground
prong
3-prong
ground
plug
3-prong
ground-
type
outlet
(double
outlet)
Power
supply
cord
Electrical Shock Hazard
Plug into a grounded 3-prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can
result in death, fire, or electrical shock.