Install Evaporator Coil
IMPORTANT:
The evaporator coil must be installed in the discharge
(supply) air of a gas or oil furnace. Do not install an
evaporator coil in the return air, or excessive condensation
will occur within the furnace.
Install the evaporator coil level with the drain connection to
ensure proper drainage.
To prevent damage to the plastic drain pan, minimum spacing
is required between the drain pan and a furnace heat
exchanger. A minimum spacing of 2 in. is required for a gas
furnace. A minimum spacing of 4 in. is required for an oil-fired
furnace. See Evaporator Coil Drain Pan Clearances.
Evaporator Coil Drain Pan Clearances
If the plenum duct work is larger than the drain pan in any
direction, the gaps between the drain pan and the plenum
walls must be closed off to prevent bypass of air around the
sides of the drain pan. Use field fabricated sheet metal angles
wide enough to support the coil where the drain pan is
located and attach them to the inside of the plenum. The
drain pan will rest on the metal angles. If the connection
between the plenum and any duct occurs below the apex of
the coil, seal this seam with sealant.
Counterflow (Downflow) Models
Metal air seals must be placed on the inside of the
evaporator's drain pan to prevent water spray in all
counterflow model installations as shown. Air Seal Kit, Part
No. ACFAIRSEAL-1, is available. The kit contains 4 air seals,
enough to complete 2 counterflow installations.
Air Seal Installation (Counterflow Models Only)
Installing Air Seals During Evaporator Coil Installation
Install the air seals, hooking the top flange over the internal sides
of the drain opening as shown.
Side View of Drain Pan
NOTE: Not installing the air seals correctly may result in property
damage due to condensate water being drawn into the furnace.
1. Furnace heat exchanger
2. Plastic drain pan
1
Gas 2" Minimum
Oil-fired 4" Minimum
2
1. Air seals before installation
2. Air seals installed
1. Air seal
2. Drain pan
1
2
1
2
Page view 3