F. CONNECT CONTROL BOX - 230V, 50 HZ
Connect service to the field wiring compartment of the
control box. The 50 Hz model control box contains blue
and brown wires and earth lug.
A 230V, 15A, 50 Hz dedicated circuit is required. Provide
an Earth Leakage Circuit Breaker.
Provide a separate equipment earthing conductor for the
inside earth lug. The earthing conductor must not be
connected to any current carrying conductor. Follow
local electrical codes. A 230 V, 15A, 50 Hz separate
circuit is required.
Earth
(Ground) Lug
Earth
(Ground)
Neutral
Earthing Lug (for
bonding in accor-
dance with national
and local codes)
Blue
(Neutral)
Brown
(Phase)
Wire Connectors
Phase (Line)
9. WATER TEST WHIRLPOOL & ELECTRONICS
Check all electrical connections. Make sure both
connections to the pump are securely tightened.
Fill bath to a level at least 2” above the top of the highest
jet.
Operate whirlpool for 5 minutes and check all whirlpool
harness (piping) connections for leaks.
For additional information on whirlpool operation, see
Whirlpool Start-Up Instructions on page 14.
10. COMPLETE FINISH WALL
CAUTION: Risk of product damage. Do not
support the weight of the whirlpool by the rim.
Protect whirlpool surface. Install finished deck. Cover
framing and walls with gypsum wallboard.
Framing
Subwall
Wallboard
Finished
Deck
Access Panel
Tape and mud drywall...seal drywall and joints under
bath rim. Install finished wall material to subwall. Seal
joints between the whirlpool rim and finished wall using
silicone sealant.
Gypsum Wallboard
Finished
WallCovering
2 x 4 Stud
Water Resistant
Sealer
Finished
Deck