WIRING DIAGRAM—WPH43(24-48)AH
Goodman 6 Long
HIGH VOLTAGE!
WARNING
Disconnect ALL power before servicing.
Multiple power sources may be present.
Failure to do so may cause property damage, personal injury or death.
W
NOTE #4
FC
NOTE#2
EM
M1
COM
TR
24 V
208-240
NO
EBTDR
C
N
3
Control
Box
240
O
PR
20 8-240 /1/60
Supply Voltage
C
COMP
C
S.A.
S
T1
R
FC
L1
BR
C
NOTE # 5
H
F
RCCF
CM
HVDR
T2
CH
C
BK
BK
L2
DF1
BK
R
PR
BK
DF2
HVDR
LVD R
R
R
R
R
R
R
BK
O BK
K1
K1
M1
DC
XFMR-C
PR
Speed
Up
C
BU
XFMR-R
R
G
EBTDR
G
COM
BU
Y
C
Y
NC
R
NO
R
2
24V
BU
208
C
BK
1
PR
COMP
CM
OR
NOTE #3
CH
BR
BR
PR
4
1
PLF
PR
BK
Y
S
BK
R
BK
5
6
2
3
Bushing
CR
R
OR
BU
BR
W
G
Y
R
O
C
W2
W1
G
Y
T
h
e
r
m
o
s
t
a
t
T2
T1
R
NOTE #4
PR
BU
L1
Y
GND
C
L2
PR
BK
6
0
/
/
1
0
4
2
-
8
0
2
High
(TRANS240 V)
PR (M 1)
R
BR
FC
Low
2 Speed
Optional
BR
EM
3 Speed
EM
M2
M2
7
8
9
PR
BU
BR
W
R
R
BK
BK
R
Y
BK
BK
R
DF T
RVC
LPS
++
EBTDR
R
G
C
DC
DF T
Y
C
DFT
EBTDR
LVD R
W2
O
R
R
13
2
LVJB
OR
OR
BU
BU
See NOTE #6
See NOTE #3
Thermosta t
BK
BK
PR
Y
RCCF
R
R
SA
Y
H C
F
BR
BU
BR
BK
(If Used)
See NOTE #5
R W2 O W1 G C
P
L
F
6
5
4
C
Y
O
RVC
24
(COM)
BK
4
2
1 3
1
3
3
1
BR
P
L
F
OR
OR
R
OR
HPS
LPSHPS
Factory Wiring
Line Voltage
Low Voltage
Optional High Voltage
Field Wiring
High Voltage
Low Voltage
C
CM
COMP
DC
DFT
GND
HPS
HVDR
LPS
LVDR
LVJB
PLF
RVC
RCCF
SA
TR
VSM
VSTB
Contactor
Condenser Motor
Compressor
Defrost Control
Defrost Thermostat
Equipment Ground
High Pressure Switch
High Voltage Defrost Relay
Low Pressure Switch
Low Voltage Defrost Relay
Low Voltage Junction Box
Female Plug Connector
Reversing Valve Coil
Run Capacitor for Compressor and Fan
Start Assist
Transformer
Variable Speed Motor
Variable Speed Terminal Block
Component Legend
BK
BU
BR
G
OR
PR
R
W
Y
Black
Blue
Brown
Green
Orange
Purple
Red
White
Yellow
Symbol
Color
R
R
R
NOTES:
Replacement wire must be the same size and type insulation as the original (at least 105ºC). Use copper conductor only.
To change evaporator motor speed, replace the lead on EBTDR "COM" with lead on EBTDR "M1 or "M2."
Crankcase heat not supplied on all units.
For 208-volt transformer operation, move the purple wires from Terminal 3 to Terminal 2 on transformer.
Start Assist factory-equipped, when required.
Use copper conductors only.
++ Use N.E.C. Class 2 wire.
See unit rating plate for the type and sixe of overcurrent protection.
Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.