Fuses smaller than that recommended on the wiring diagrams
could result in unnecessary fuse failure or service calls. The use
of protective devices of larger size than indicated could result in
extensive damage to the equipment. The manufacturer bears no
responsibility for damage caused to equipment as result of the
use of larger than is recommended size protective devices.
All units have undergone a run test prior to packaging for
shipment. This equipment has been started at minimum rated
voltage and checked for satisfactory operation. Do not attempt to
operate this unit if the voltage is not within the minimum and
maximum voltages shown on nameplate.
All exterior wiring must be within approved weatherproof conduit.
The unit must be permanently grounded in accordance with local
codes, or in absence of local codes, with N.E.C. ANSI/ NFPA No.
70-1984 or latest edition by using ground lug in the control box.
Fuses or HACR-type circuit breakers may be used where codes
permit.
NOTE: Some single-phase units are equipped with a single-pole
contactor. Caution must be exercised when servicing as only
1 leg of the power supply is broken with the contactor.
To wire the unit, make the following high and low voltage
connections:
High Voltage Wiring
Single Phase—2 leads should be connected to terminals L1 and
L2 in the electrical control section, using wire sizes specified in
the wiring table.
Low Voltage Wiring
Air Conditioners—Connect 24V wires from the thermostat to
the corresponding wires in the control box using 18 AWG as
follows:
*Optional field installed heat connections
Heat Pumps—Connect 24V wires from the thermostat to the
corresponding wires in the control box using 18 AWG as
follows:
*Optional field installed heat connections
Internal Wiring
A diagram detailing the internal wiring of this unit is located on
the electrical box cover. If any of the original wire supplied with
the appliance must be replaced, the wire gauge and insulation
must be the same as the original wiring.
Transformer is wired for 230 volts on the 208/230 models. See
the wiring diagram for 208-volt wiring.
For branch circuit wiring (main power supply to unit
disconnect), the minimum wire size for the length of the run
can be determined from the Branch Circuit Ampacity chart
using the circuit ampacity found on the unit rating plate. From
the unit disconnect to the unit, the smallest wire size
allowable in the Branch Circuit Ampacity chart may be used
for the ampacity, as the disconnect must be in sight of the
unit.
Wire size based on 60ºC rated wire insulation and 86ºF (30ºC)
ambient temperature.
For more than 3 conductors in a raceway or cable, see the
N.E.C. for derating the ampacity of each conductor.
Voltage Wiring
Lead Thermostat
Red R (24V)
Green G (Fan)
Yellow Y (Cool)
White W1 (Heat)*
Brown W2 (Heat)*
Goodman 6
HIGH VOLTAGE!
WARNING
Disconnect ALL power before servicing.
Multiple power sources may be present.
Failure to do so may cause property damage,
personal injury or death.
Lead Thermostat
Red R (24V)
Green G (Fan)
Orange O (Rev. Valve)
White W1 (Heat, 2
nd
)*
Brown W2 (Heat, 3
rd
)*
Yellow Y (Cool)
C (Blue) C (Common
Branch Circuit Ampacity
Supply Wire
Length—ft (m) 15 20 25 30 35 40 45 50
200 (61) 64443322
150 (45.7) 86644433
100 (30.5) 108866644
50 (15.2) 14 12 10 10 8 8 6 6
R
W
G
GW
For Internal Wiring, See Wiring Label Attached To Unit
Low Voltage Connectors
Y
Cool
Fan
Common
Heat
Y
R
T1
T2
L1
L2
High Voltage Power Wiring
24-Volt Control Wiring
High Voltage
Disconnect
Switch
Thermostat Subbase
Contactor