Whirlpool Automatic Ice Maker User Manual Page 3

  • Download
  • Add to my manuals
  • Print
  • Page
    / 34
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 2
3
SECTION TWO
THEORY OF OPERATION
OPERATING SYSTEMS
There are three operating systems in the ice maker:
Refrigeration System
Water System
Electrical System
Refrigeration System
The refrigeration system in the ice maker is very similar to the system used in other refrigeration
appliances such as a refrigerator or freezer. The refrigerant used in this unit is R-134a.
There are two very important additions to the refrigeration system in the ice maker:
Hot Gas Valve - This valve allows high pressure refrigerant gas to bypass the condenser and
flow through the condenser accumulator tube.
Condenser Accumulator Tube - the hot gas pushes liquid refrigerant in the accumulator tube
into the evaporator, helping to evenly heat the evaporator plate so the ice slab releases quickly
and evenly.