WARNING
Electrical Shock Hazard
Disconnect power before
servicing.
Replace all parts and panels
before operating.
Failure to do so can result in
death or electrical shock.
FOR SERVICE TECHNICIAN’S USE ONLY
Voltage Measurement Safety Information
When performing live voltage measurements, you must do the following:
Verify the controls are in the off position so that the appliance does not start when energized.
Allow enough space to perform the voltage measurements without obstructions.
Keep other people a safe distance away from the appliance to prevent potential injury.
Always use the proper testing equipment.
After voltage measurements, always disconnect power before servicing.
Do not Discard
Tech Sheet
DANGER
Electrical Shock Hazard
Only authorized technicians should
perform diagnostic voltage measurements.
After performing voltage measurements,
disconnect power before servicing.
Failure to follow these instructions can
result in death or electrical shock.
Kw/24 hr ±0.4
70° 90° 110°
.95 1.50 2.1
Percent Run Time
±10
70° 90° 110°
35 50 70
Cycles/24 hr
±10
70° 90° 110°
30 30 30
Refrigerator Compartment
Average Food Temperature
±4°F
70° 90° 110°
38 38 38
Freezer Compartment
Average Food Temperature
±4°F
70° 90° 110°
0 0 0
No-Load Performance, Controls in Normal Position
Ambient °F
Evaporator
Outlet
±3°F
70° 90°
-18 -15
Evaporator
Inlet
±3°F
70° 90°
-18 -15
Suction Line
±10°F
70° 90°
75 95
Average Total
Wattage ±20%
70° 90°
110 120
Suction
Pressure
±3 PSIG
70° 90°
-2 0
Head
Pressure
± 5 PSIG
70° 90°
100 140
Temperature Relationship Test Chart
Ambient °F
Component Specifications
Component
Compressor
Relay
Compressor run
capacitor
Electric damper control
Thermistor
Condenser motor
Evaporator fan motor
Overload/Relay
Thermostat (Defrost)
Evaporator heater
(19 Cu. Ft)
Evaporator heater
(22 Cu. Ft)
Evaporator heater
(20, 25 Cu. Ft)
Control board
Water Valve,
dual (if equiped)
Light switch
Light switch / Interlock
Specifications all parts
115VAC/60HZ unless noted
BTUH.......................................................
Watt..........................................................
Current Lock rotor....................................
Current Full load......................................
Resistance Run windings........................
Resistance Start windings.......................
Volt...........................................................
Capacitance.............................................
Maximum closing time.............................
Temperature Rating.................................
RPM.........................................................
Temperature.............................................
77°F..........................................................
36°F..........................................................
0°F............................................................
Rotation (facing end opposite shaft)........
RPM.........................................................
Watt..........................................................
Current.....................................................
Rotation (facing end opposite shaft)........
RPM.........................................................
Watt..........................................................
Note: Fan blade must be fully seated
on shaft to achieve proper airflow.
Ult. trip amps @ 158°F (70°C)................
Close temperature.................................
Open temperature.................................
Short time trip (seconds).........................
Short time trip (amps @77°F (25°C).......
Volt...........................................................
Watt..........................................................
Current.....................................................
Resistance across terminals:
Above 42°F ±5°.......................................
Below 12°F ±7°........................................
Volt...........................................................
Wattage....................................................
Resistance...............................................
Volt...........................................................
Wattage....................................................
Resistance...............................................
Volt...........................................................
Wattage....................................................
Resistance...............................................
Volt...........................................................
See control board section for
diagnostics
Volt...........................................................
Wattage....................................................
Type.........................................................
Volt...........................................................
Current.....................................................
Type.........................................................
Volt...........................................................
Current.....................................................
660 BTUH Embraco
EM2Y60
60 Hz / 117 watts
10.8 amps± 15%
1.60 amps± 15%
4.75 ohms± 8%
6.1 ohms± 8%@77°F
TSD2/5sP
180 VAC
12 µfd ± 10%
8 seconds
20°F- 110°F
5
Resistance
10,000 ohms± 1.8%
29,500 ohms± 1.0%
86,300 ohms± 1.8%
Clockwise
1120 RPM
3.4 watts±15%@115VAC
0.085 amps± 15%@115VAC
Clockwise
2800 RPM
3.7 or 6.0±15% watts@115
VAC
2.74 amps± 15%
142°F ±16°
248°F ±9°
10 seconds ±5
12 amps ±2amps
120/240 VAC
495 watts
10/5 amps
56 K ohms
Open
Closed
115 VAC
395 ±5% watts @ 115VAC
33 ±5% ohms
115 VAC
435 ±5% watts @ 115VAC
30 ±5% ohms
115 VAC
470 ±5% watts @ 115VAC
28 ±5% ohms
120 VAC,60HZ
120 VAC
35 watts (Brown Coil)
20 watts (Yellow Coil)
SPDT NC
125/250 VAC
8 / 4 amps
SPDT NO/NC
125/250 VAC
8 / 4 amps
Control board Troubleshooting
Programming Mode:
Note: The Program Code is located on the Serial Plate on this unit after the word Code.
1. Open the Fresh Food door and hold the Fresh Food door light switches closed while pushing the Freezer
Temperature DOWN /- Key pad 3 times consecutively.
Note: The 3 Keystrokes must be done consecutively and within 10 seconds.
2. Release the Fresh Food door light switch.
3. The control will display P- Eto confirm entry into the programming mode.
4. Entry is confirmed by pressing the Freezer Temperature DOWN /- key once more.
Note: All control functions will be turned off (Compressor, Defrost, Evaporator Fan, the damper will remain in its
current position).
5. The control will display the current Program Code. This value should be validated with the Program Code
printed on the unit serial plate.
Note: If the Program Code is correct, the Programming Mode is exited by closing the Refrigerator door(s).
6. To set the desired Program Code number press the Freezer and Refrigerator UP /+ keys. The corresponding
digit will be advanced with each key press.
7. Once the desired Program Code is displayed, press the Freezer Temperature DOWN /- Key until the Program
Code begins flashing indicating it has been saved.
Note: If you attempt to enter an invalid Program Code the control will not save the new code, but will flash the old
code and this will be displayed. (The unit will NOT run with a Program Code of OO).
8. Once the Program Code has been saved the Programming Mode is exited by closing the Refrigerator door(s).
If the new code is incorrect this process should be repeated after closing the Refrigerator door(s).
The Programming mode can be exited at any time by closing the Refrigerator Door(s).
Defrost Operation:
The Control Board adapts the compressor run time between defrosts to achieve optimum defrost intervals by
monitoring the length of time the defrost heater is on.
After initial power up, defrost interval is 4 hours compressor run time. Defrost occurs immediately after the 4 hours.
Note: Once unit is ready to defrost there is a 4 minute wait time prior to the beginning of the defrost cycle.
Optimum defrost is 15 minutes. Each additional minute the defrost thermostat remains closed, 1 hr. is subtracted
from the previous defrost interval. Each minute the thermostat opens prior to optimum defrost, it extends the next
defrost interval 1 hr. When defrost thermostat opens there is a 4-6 minute drip time before compressor restarts or
Control Board will terminate defrost at 25 minutes if defrost thermostat has not opened and will reset the defrost
interval to the 8 hr. minimum setting.
4 hours of continuous compressor run resets the next defrost interval to 8 hours and will initiate a defrost, if 8 hours
of compressor run time has also occurred.
Forced Defrost Mode:
The forced defrost function is performed using the refrigerator display and keypad. Enter the Forced Defrost Mode
by performing the following sequence of events:
1. Hold the refrigerator door light switch closed.
2. Press the Refrigerator Temperature DOWN /- keypad 3 times consecutively.
Note: The 3 keystrokes must be consecutive and within 10 seconds.
3. Release the refrigerator door light switch.
4. The control will display F- d to confirm entry into the Forced Defrost Mode.
5. Entry is confirmed by pressing the Refrigerator Temperature DOWN /- key once more. The unit is off and in
the Defrost Mode.
Note: All control functions will be turned off (Compressor, Defrost, Evaporator Fan, the damper will remain in its
current position).
6. The control will default to the short run period test.
Note: You can toggle between the S Short and L Long test mode by pressing the Refrigerator Temperature UP /+
Key. Long Test mode is used for factory test and should not be used in the field.
7. Once the desired mode is displayed, confirm the forced defrost by pressing the Refrigerator Temperature
DOWN /- Key once. The defrost will begin immediately and the display will return to a normal operating display
with set point values.
8. Close the Refrigerator door(s). You are in the defrost mode.
Note: Forced Defrost mode can be exited at any time prior to step 7 by closing the Refrigerator Door(s).
Service Test Mode:
The service test functions are performed using the Refrigerator Temperature Display and Keypad. Enter the
Service Test Mode by performing the following sequence of events:
1. Hold the refrigerator door light switch closed.
2. Press the Refrigerator Temperature UP /+ keypad 3 times consecutively.
Note: The 3 keystrokes must be done consecutively and within 10 seconds.
3. Release the refrigerator door light switch.
4. The control will display S - E to confirm entry into the service mode.
5. Entry to the Service Menu is confirmed by pressing the Refrigerator UP /+ key once more.
6. The control will display its software version for 3 seconds.
7. Following the software revision display the freezer display will read the first test number in the diagnostic tree.
The refrigerator display will be blank.
Note: All control functions will be turned off (Compressor, Defrost, Evaporator Fan, the damper will remain in its
current position).
8. You are now in the SERVICES TEST operational mode and may use the diagnostic tests.
The Service Test Mode can be exited at any time by closing the Refrigerator Door(s).
The Freezer Temperature UP /+ DOWN /- keys allow selection of the test to be performed.
Service Test 1 - Defrost Thermostat & Defrost Circuit Test
When selected this test will display the state of the defrost thermostat. In order to perform this test the defrost
heater will be energized. The test is activated and deactivated using the Refrigerator Temperature UP /+ key.
Once activated, this test must be deactivated to move to another test number.
This test also allows observation and measurement of proper defrost function. You can observe defrost heat and
voltages while the test is activated. For Defrost Thermostat (Open), freezer displays 1 and refrigerator displays O.
For Defrost Thermostat Shorted (Closed), freezer displays 1 and refrigerator displays S.
Service Test 2 - Compressor/Condenser Fan Test
When selected and activated this test will operate the Compressor/Condenser Fan circuit. You should evaluate
proper operation of the compressor and condenser fan. The Refrigerator Temperature UP /+ key will toggle
between O / F (ON & OFF) the compressor drive circuit. The test must be "deactivated" or in the OFF position to
move to another test selection. Observe Compresser and Condenser Fan Function, Freezer displays 2
Refrigerator displays 0 (ON) or freezer displays 2 and refrigerator displays F (OFF).
Service Test 3 - Evaporator/Freezer Fan Test
When selected and activated this test will operate the freezer fan. The Refrigerator Temperature UP /+ key will
toggle between O / F (ON & OFF) the fan drive circuit. You will have to inspect the fan for proper function. The
test must be "deactivated" or in the OFF position to move to another test selection. Observe Fan Operation,
Freezer displays 3 - Refrigerator displays O or F.
Service Test 4 - Fresh Food Thermistor Test
When selected the refrigerator displays P=Pass, O=Open, S=Short result for a test on the Fresh Food Thermistor
circuit. The test is activated and de-activated via the Refrigerator Temperature UP /+ key, and must be
de-activated to move to another selection. Freezer displays 4 - Refrigerator will be P, O or S.
Service Test 5 - Freezer Thermistor Test
When selected the refrigerator displays P=Pass, O=Open, S=Short result for a test on the Freezer Thermistor
circuit. The test is activated and de-activated via the Refrigerator Temperature UP /+ key, and must be
de-activated to move to another test selection. Freezer displays 5 - Refrigerator will be P, O or S.
Service Test 6 - Open Damper Test
When selected and activated this test will indicate the current position O / C (OPEN / CLOSED) of the refrigerator
damper. The Refrigerator Temperature UP /+ key will toggle the damper open and closed. You must allow 1
minute for each attempt to change the damper position. You should observe proper damper function. Freezer
displays 6 - Refrigerator will be O or C.
Note: Adjustments of Service Test 7 or Service Test 8 will alter the performance of the unit.
Service Test 7 - FF Performance Adjustment
This test will allow adjustment of the control performance points. Each step will incrementally change the
Refrigerator performance warmer 1° towards 1 or colder 1° towards 9
as adjusted. The default value is 5. The
Refrigerator Temperature UP /+ and DOWN /- keys are used to adjust the Performance Offset value.
WARMER <(1 2 3 4 (5) 6 7 8 9)> COLDER
The last FF Performance Offset value displayed before leaving test 7 will be saved when the refrigerator door(s) is
closed.
Service Test 8 - FZ Performance Adjustment
This test will allow the adjustment of the control performance points. Each step will incrementally change the
Freezer performance 1° warmer towards (1) or 1° colder towards (9). The default value is 5. The Refrigerator
Temperature UP /+ and DOWN /- keys are used to adjust the Performance Offset value.
WARMER <(1 2 3 4 (5) 6 7 8 9)> COLDER
The last FZ Performance Offset value displayed before leaving test 8 will be saved when the refrigerator door(s) is
closed.
Service Test 9 - Defrost Adjustment
This test will allow the adjustment of the defrost interval from adaptive defrost time to a fixed defrost time.
The Refrigerator Temperature UP/+ key will toggle from (A) Adaptive to (F) Fixed, 6 hour defrost time. Default
setting is Freezer displays 9 - Refrigerator displays A. For Fixed Defrost Freezer displays 9 - Refrigerator
displays F.
JZ 19-22 2 door & FD 5/10
W10322959B
Page view 0
1 2

Summary of Contents

Page 1 - Control board Troubleshooting

WARNINGElectrical Shock HazardDisconnect power before servicing.Replace all parts and panelsbefore operating.Failure to do so can result indeath or el

Page 2 - Schematic

Wiring DiagramJZ 19-22 2 door & FD 5/10NOTE: This sheet contains important Technical Service Data.FOR SERVICE TECHNICIAN ONLYDO NOT REMOVE OR

Comments to this Manuals

No comments